Continuous wavelet analysis of postprandial EGGs suggests sustained gastric slow waves may be slow to develop in infants with colic.

Neurogastroenterol Motil

School of Food, Nutrition and Human Health, College of Health, Massey University, Palmerston North, New Zealand.

Published: March 2017

Background: Electrogastrography in conjunction with Fast Fourier transform has limited success in detecting low grade abnormalities in gastric electrophysiological activity owing to the non-stationarity of the signal. Analysis by continuous wavelet transform is suitable for non-stationary signals and was used to analyse EGG activity in babies with and without colic.

Methods: Thirty minute postprandial EGG recordings were obtained from 23 sleeping breast-fed infants with clinically validated recurrent colic and 26 breast-fed non-colicky infants. Continuous wavelet transform analysis (CWT) identified three principal frequency components. The mean, standard deviation, and the number of frequency maxima that fell below one standard deviation from the mean were determined for each infant and each frequency.

Key Results: Three component frequencies in the ranges 1.4-2.5 cpm, 2.5-4.0 cpm, and 4.0-15 cpm were found in all EGGs. Pairwise comparisons of the characteristics of each of the frequency ranges by univariate analyses showed significant differences between colicky and non-colicky subjects only in the number of maxima in the mid range of frequencies that lay below one standard deviation from the mean. However, CWT based on all frequencies allowed discrimination of the EGGS of colicky from non-colicky babies on a basis of number of frequency maxima below one standard deviation from the mean in the midrange of frequencies and in the mean and standard deviation in the low range of frequencies that was likely a harmonic of the midrange.

Conclusions & Inferences: CWT allowed distinction of EGG signals from colicky and healthy babies. The results indicate that colic may result from tardiness in the establishment of coherent propagation of the gastric slow wave in colicky babies.

Download full-text PDF

Source
http://dx.doi.org/10.1111/nmo.12948DOI Listing

Publication Analysis

Top Keywords

standard deviation
20
continuous wavelet
12
gastric slow
8
wavelet transform
8
number frequency
8
frequency maxima
8
colicky non-colicky
8
range frequencies
8
standard
5
deviation
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!