Gait initiation (GI) involves passing from bipedal to unipedal stance. It requires a rapid movement of the center of foot pressure (CoP) towards the future swing foot and of the center of mass (CoM) in the direction of the stance foot prior to the incoming step. This anticipatory postural adjustment (APA) allows disengaging the swing leg from the ground and establishing favorable conditions for stepping. This study aimed to describe the neuro-mechanical process that underlies the goal-directed medio-lateral (ML) APA. We hypothesized that controlled knee flexion of the stance leg contributes to the initial ML displacement of the CoP and to the calibration of the first step. Fourteen subjects initiated gait starting from three different initial stance widths of 15 cm (Small), 30 cm (Medium), and 45 cm (Large). Optoelectronic, force platform and electromyogram (EMG) measurements were performed. During APA, soleus activity diminished bilaterally, while tibialis anterior (TA) activity increased, more so in the stance leg than in the swing leg, and to a larger extent with increasing initial stance width. Knee flexion of the stance leg was observed during APA and correlated with the ML CoP displacement towards the swing leg. ML CoP and CoM displacements during APA increased with increasing stance width. The activity of stance-leg TA was correlated with the degree of knee flexion. Swing-leg tensor fasciae latae (TFL) was also active during APA. Across subjects, when stance-leg tibialis activity was low, TFL activity was large and vice versa. The modulation of the ML CoP position during APA allowed the gravity-driven torque to place the CoM just lateral to the stance foot during step execution. Accordingly, the gravity-driven torque, the ML CoM velocity during step execution, and the step width at foot contact (FC) were lower in the Small and greater in the Large condition. Consequently, the position of the stepping foot at FC remained close to the sagittal plane in all three conditions. Conclusively, coordinated activation of hip abductors and ankle dorsiflexors during APA displaces the CoP towards the swing leg, and sets the contact position for the swing foot.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5015477 | PMC |
http://dx.doi.org/10.3389/fnhum.2016.00445 | DOI Listing |
J Biomech Eng
January 2025
Department of Mechanical Engineering, Vanderbilt University, 2201 West End Avenue, Nashville, TN, 37235.
Achilles tendon overuse injuries are common for long-distance runners. Ankle exos (exoskeletons and exosuits) are wearable devices that can reduce Achilles tendon loading and could potentially aid in the rehabilitation or prevention of these injuries by helping to mitigate and control tissue loading. However, most ankle exos are confined to controlled lab testing and are not practical to use in real-world running.
View Article and Find Full Text PDFSports Med Open
January 2025
Department of Health, Nutrition, and Food Sciences, Florida State University, Tallahassee, FL, USA.
Background: Little is known about the lower extremity muscle co-contraction patterns during sprinting and its relation to running velocity (i.e., performance).
View Article and Find Full Text PDFAnn Biomed Eng
December 2024
Department of Mechanical Engineering, The Biorobotics and Biomechanics Lab, University of Maine, 168 College Ave, Orono, ME, 04469, USA.
Purpose: Current gait rehabilitation protocols for older adults typically attempt to effect changes in leg movements, while the role of arm movements is often ignored despite evidence of the neurological coupling of the upper and lower extremities. In the present work, we examine the effectiveness of a novel wearable haptic cueing system that targets arm swing to improve various gait parameters in older adults.
Methods: Twenty participants ( years) were recruited to analyze their gait during normal and fast walking without haptic cueing.
Sports (Basel)
November 2024
Department of Martial Arts and Power Sports, National University of Physical Education and Sport, 03150 Kyiv, Ukraine.
Background/objectives: This study aims to investigate the daily variations in upper and lower body power performance in adolescent volleyball players.
Methods: The sample consisted of 50 young male volleyball players (14.12 ± 0.
Med Eng Phys
December 2024
Department of Mechanical Engineering, IIT Madras, Chennai, India. Electronic address:
Gait simulators play a crucial role in assessing the performance of physical prototypes of prosthetic knees, validating numerical simulation findings, and reducing dependency on user trials during prosthesis development. However, their practical application is limited because of substantial capital investment required for sophisticated high degrees-of-freedom (DOF) system development on one side and insufficient DOF for accurate simulation on the other. In this study, we evaluated the minimum DOF of thigh segment that a gait simulator should have to test the performance of prosthetic knees in a cost-effective manner.