Introduction: The purpose of this study was to investigate the fracture resistance of roots by using intraorifice barriers with glass fiber-incorporated ProRoot MTA and Biodentine.

Methods: The diametral tensile strength and compressive strength of ProRoot MTA and Biodentine were determined after incorporation of 5 wt% and 10 wt% alkali resistant (AR) glass fiber powder into both cements. On the basis of higher diametral tensile strength and compressive strength values, ProRoot MTA and Biodentine with 5 wt% AR glass fiber were selected for further testing as intraorifice barriers. The 14-mm-long root specimens obtained from extracted mandibular premolars (n = 60) were prepared with nickel-titanium rotary files and obturated with gutta-percha + AH Plus sealer. After removal of coronal 3 mm of root fillings, the roots were grouped with respect to the intraorifice barrier material (n = 12/group): (1) ProRoot MTA, (2) ProRoot MTA with 5 wt% AR glass fibers, (3) Biodentine, (4) Biodentine with 5 wt% AR glass fibers, and (5) control (no intraorifice barrier). The specimens were loaded vertically at 1 mm/min crosshead speed until vertical root fracture occurred. The data were evaluated statistically by using 2-way analysis of variance and Tukey tests.

Results: Both incorporation of glass fiber and the type of material significantly affected fracture resistance (both P = .002). Roots with glass fiber-reinforced Biodentine barriers showed the highest fracture strength (P = .000).

Conclusions: Incorporation of 5 wt% AR glass fiber can significantly improve the reinforcement effect of ProRoot MTA and Biodentine when used as intraorifice barriers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.joen.2016.08.002DOI Listing

Publication Analysis

Top Keywords

proroot mta
28
mta biodentine
16
intraorifice barriers
16
glass fiber
16
wt% glass
16
glass fiber-incorporated
8
fiber-incorporated proroot
8
biodentine intraorifice
8
fracture resistance
8
glass
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!