Optic nerve sheath diameter quantification by transbulbar B-mode sonography is a recently validated technique, but its clinical relevance in relapse-free multiple sclerosis patients remains unexplored. In an open-label, comparative, cross-sectional study, we aimed to assess possible differences between patients and healthy controls in terms of optic nerve sheath diameter and its correlation with clinical/paraclinical parameters in this disease. Sixty unselected relapse-free patients and 35 matched healthy controls underwent transbulbar B-mode sonography. Patients underwent routine neurologic examination, brain magnetic resonance imaging and visual evoked potential tests. The mean optic nerve sheath diameter 3 and 5 mm from the eyeball was 22-25% lower in patients than controls and correlated with the Expanded Disability Status Scale (r = -0.34, p = 0.048, and r = -0.32, p = 0.042, respectively). We suggest that optic nerve sheath diameter quantified by transbulbar B-mode sonography should be included in routine assessment of the disease as an extension of the neurologic examination.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultrasmedbio.2016.07.018 | DOI Listing |
Brain Res
May 2020
Department of Neurology, Firoozgar Hospital, Iran University of Medical Sciences (IUMS), Tehran, Iran. Electronic address:
Objective: Trans bulbar B-mode sonography (TBS) is a recently proposed method but there is little known about its diagnostic accuracy in patients with multiple sclerosis without acute optic neuritis. Therefore we assessed the correlation between OND, ONSD and OND/ONSD ratio with clinical/para clinical parameters.
Methods: In a comparative study, we intended to examine possible differences in optic nerve diameter (OND) and optic nerve sheath diameter (ONSD) between 60 patients with multiple sclerosis (MS) and 60 individuals as matched healthy controls.
Ultrasound Med Biol
February 2018
Multiple Sclerosis Centre, Complex Operative Neurology-Stroke Unit, "F. Ferrari" Hospital, Casarano-Lecce, Italy.
Ultrasound Med Biol
February 2018
Department of Medicine, Surgery and Dentistry "Scuola Medica Salernitana", University of Salerno, Salerno, Italy.
Ultrasound Med Biol
December 2016
Department of Biological and Environmental Sciences and Technologies, Laboratory of Hygiene, University of the Salento-Lecce, Italy.
Optic nerve sheath diameter quantification by transbulbar B-mode sonography is a recently validated technique, but its clinical relevance in relapse-free multiple sclerosis patients remains unexplored. In an open-label, comparative, cross-sectional study, we aimed to assess possible differences between patients and healthy controls in terms of optic nerve sheath diameter and its correlation with clinical/paraclinical parameters in this disease. Sixty unselected relapse-free patients and 35 matched healthy controls underwent transbulbar B-mode sonography.
View Article and Find Full Text PDFUltrasound Med Biol
May 2015
Department of Neurology, University Hospital Frankfurt, Frankfurt am Main, Germany. Electronic address:
Two ultrasound tests that can be used to assess increased intracranial pressure (ICP) at the bedside are described. In outpatients receiving lumbar puncture and in intensive care patients with invasive ICP monitoring, we measured the optic nerve sheath diameter (ONSD) with transbulbar B-mode sonography and septum pellucidum undulation (SPU) induced by repeated passive head rotation with transtemporal M-mode sonography. We assessed the sensitivity and specificity of ONSD and SPU in the prediction of ICP >20 cm H2O.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!