We assessed the performance of a portable glucose meter in a tropical environment. This was undertaken in an effort to reduce the costs of regular blood glucose measurements for our diabetic patients, many of whom were finding regular laboratory tests financially burdensome. The glucose meter was as accurate as the laboratory up to glucose concentrations of 250 mg/dl (14 mmol/l) but slightly overestimated results above that level. Nevertheless, it gave results comparable to those obtained with similar instruments in temperate countries, with a correlation coefficient of 0.91. Its cheapness, alternative power source from dry battery, use of finger prick capillary rather than venous blood, ease of operation, and quick production of results make it almost ideal for use in developing countries.
Download full-text PDF |
Source |
---|
Medicine (Baltimore)
January 2025
Department of Clinical Laboratory, Zhejiang Hospital, Hangzhou, Zhejiang, China.
To evaluate the accuracy of home self-monitoring portable blood glucose meters, we analyzed the current problems of patients using portable blood glucose meters and put forward reasonable suggestions. A self-designed questionnaire was used to survey 142 patients and 132 healthcare professionals. The questionnaire consisted of 16 items with an overall score ranging from 1 to 13 (with a higher score indicating better experience).
View Article and Find Full Text PDFDiabetes Obes Metab
January 2025
School of Medicine, Western Sydney University, Campbelltown, New South Wales, Australia.
Aims: Physiological changes during pregnancy can infuence the performance of blood glucose meters. This study aimed to evaluate the analytical and clinical accuracy of glucose meters in pregnant women with hyperglycaemia.
Materials And Methods: Glucose was measured by four commonly used meters among consecutive women with diabetes in pregnancy.
Vet Sci
January 2025
Programa de Pós-Graduação em Ciências Veterinárias, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre 91540-000, Brazil.
Pregnant ewes are susceptible to hypoglycemia and ketosis; therefore, monitoring glycemic status is extremely important. Portable blood glucose meters (PBGMs) can assist in quickly and conveniently identifying glycemic disturbances in this species, provided that they meet the criteria of analytical accuracy. This study evaluated the performance of a human PBGM (Accu-Chek Performa, Roche Diagnostics, Basel, Switzerland) in the glycemic evaluation of 34 pregnant ewes at days 90 and 120 of pregnancy in comparison with the results of glycemia determination by a reference method (RM).
View Article and Find Full Text PDFPeerJ
January 2025
Faculty of Fisheries, Muğla Sıtkı Koçman University, Muğla, Türkiye.
This study aims to determine and compare the reference values of the haematological and biochemical blood parameters of two fish species collected from the Gökova Bay (Muğla, South-Western of Türkiye): the non-native and invasive Randall's threadfin bream, and the native Common pandora, . Both species inhabit the same environment and compete for resources. Blood samples were collected from a total of 100 fish samples (50 and 50 ) which were caught from a depth of 30 to 60 meters between February 2023 and July 2024.
View Article and Find Full Text PDFIn Table 7.2, "Common interfering substances and/or conditions that affect glucose meters (for inpatient and outpatient use)," of the article cited above, the effects on glucose values measured by blood glucose meters for high and low hematocrit were incorrect. For high hematocrit, the effect would be falsely lower blood glucose values.