Despite improvements in minimally invasive techniques over recent decades, kidney implantation into the iliac fossa has remained a domain of open surgery. However, it was hypothesized that it would be feasible to perform robotic transplant kidney implantation as a means of reducing surgical trauma. Two robotic kidney transplantations into the iliac fossa were attempted in human cadavers. In the first cadaver, a 5 cm incision was placed in the right lower abdomen, the peritoneum was mobilized in a cranial direction, the iliac vessels were identified, and the kidney placed in the pre-peritoneal space. The incision was sealed with a gel port through which the Vinci(©) Surgical System was installed. In the second cadaver, a robotic kidney implantation with robotically sutured vascular and ureteric anastomoses was performed trans-abdominally. Open incision, identification, placement of gel port, and robotic docking were feasible. Robotic performance of vascular anastomosis was not possible in the first cadaver because of advanced decay and excess fat in the surgical field. Robotic kidney positioning was feasible and anastomoses were performed successfully in the second cadaver within 35, 25, and 20 min (arterial, venous, and ureteric, respectively). Robotic kidney transplantation seems feasible in human cadavers if tissue condition is suitable, but is very technically challenging. Because of the delicacy of anatomical structures, the cadaveric model with the risk of advanced decay and the absence of circulation sets limits on the exploration of this complex procedure. Hence, further research and animal work in this area is critical to improve understanding of the benefits and limitations of robotic kidney implantation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11701-010-0221-z | DOI Listing |
Arthroplast Today
December 2024
Rubin Institute for Advanced Orthopedics, LifeBridge Health, Sinai Hospital of Baltimore, Baltimore, MD, USA.
Background: As the use of robotics in total hip arthroplasty (THA) continues to gain popularity, differences in clinical outcomes when compared to manual techniques have remained unclear. This study aimed to compare postoperative complications between patients undergoing robotic-assisted techniques and manual THA for primary osteoarthritis at 90 days, 1 year, and 2 years.
Methods: Using an all-payer national database, we identified 405,048 patients who underwent either robotic-assisted or manual THA for primary osteoarthritis.
J Robot Surg
January 2025
Department of Anesthesiology, Zhujiang Hospital of Southern Medical University, Guangdong, 510000, China.
This study investigated the impact of an improved body positioning on the effectiveness of EDGE MP1000 robot-assisted laparoscopic partial nephrectomy. We compared clinical data from 39 patients who underwent the procedure at Zhujiang Hospital of Southern Medical University between November 2023 and May 2024. The control group (18 patients) received conventional positioning, while the experimental group (21 patients) received precise positioning, which included patient assessments, optimized positioning techniques, and enhanced nursing measures.
View Article and Find Full Text PDFUltrasonics
January 2025
Department of Robotics and Mechatronics, AGH University of Krakow, 30-059 Krakow, Poland. Electronic address:
Ultrasound shear wave elastography (SWE) is widely used in clinical applications for non-invasive measurements of soft tissue viscoelasticity. The study of tissue viscoelasticity often involves the analysis of shear wave phase velocity dispersion curves, which show how the phase velocity varies with frequency or wavelength. In this study, we propose an alternative method to the two-dimensional Fourier transform (2D-FT) and Phase Gradient (PG) methods for shear wave phase velocity estimation.
View Article and Find Full Text PDFTransl Androl Urol
December 2024
Department of Urology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
Background: The treatment of transplant ureteral stricture (TUS) has been a great challenge, and there is limited experience with indocyanine green (ICG) fluorescence-guided robotic Boari flap-pelvis anastomosis to identify ureteral stenosis segments (especially long-segment) and their postoperative blood supply. We report case series of ureteral strictures treated with ICG fluorescence-guided robotic Boari flap-pelvis anastomosis in our center.
Case Description: We retrospectively collected clinical data of six patients diagnosed with long-segment even full-length TUS who underwent robotic Boari flap-pelvis anastomosis with the assistance of modified distribution of robotic ports and ICG fluorescence between June 2022 and June 2024, focusing on postoperative renal function, stenosis recurrence, and urinary fistulae.
Kidney Res Clin Pract
January 2025
Department of Internal Medicine, Myongji Hospital, Hanyang University College of Medicine, Goyang, Republic of Korea.
Background: Constipation is a common gastrointestinal disorder and is often accompanied by alteration in the gut microbiota. Recently, several studies have disclosed its association with an increased risk of cardiovascular disease and mortality in the general population. Despite the high prevalence of constipation, data on the clinical impact of constipation in patients with chronic kidney disease are limited.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!