Four corner fusion using a multidirectional angular stable locking plate.

World J Orthop

Tahseen Chaudhry, Michelle Spiteri, Dominic Power, Mark Brewster, Department of Hand Surgery, Queen Elizabeth Hospital, Birmingham B15 2TH, United Kingdom.

Published: August 2016

Aim: To review the results of our experience with the Medartis Aptus plating system for four corner arthrodesis of the wrist, which uses a combination of compression screws and variable angle locking screws.

Methods: We reviewed the results of 17 procedures in 16 patients that underwent scaphoid excision and four corner fusion using the Medartis Aptus system between May 2010 and June 2014. The primary outcome measure was radiographic and clinical union.

Results: The mean clinical follow up time was 20.6 mo. The mean union time was 6 mo. Two non-unions required revision procedures. The mean disabilities of the arm, shoulder and hand score taken after union was 36. The mean final grip strength was 27 kg. The mean final range of movement was 30° flexion and 31° of extension. All patients had a restored scapholunate angle on postoperative radiographs. There were no incidences of dorsal impingement.

Conclusion: Overall our experience with the Aptus plating system shows comparable results to other methods of fixation for four corner fusion, in the short to medium term.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4990772PMC
http://dx.doi.org/10.5312/wjo.v7.i8.501DOI Listing

Publication Analysis

Top Keywords

corner fusion
12
medartis aptus
8
aptus plating
8
plating system
8
corner
4
fusion multidirectional
4
multidirectional angular
4
angular stable
4
stable locking
4
locking plate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!