Purpose: The purpose of this study was to evaluate the results of a teamwork revision endoscopic dacryocystorhinostomy (DCR) in eyes with previously failed external DCR.

Methods: This retrospective study was performed on 50 failed external DCR subjects who underwent a teamwork revision endoscopic DCR by an ophthalmologist and an otolaryngologist. Paranasal sinus CT scanning was performed for each patient before the revision surgery. During surgery, any abnormal tissue noticed before silicone intubation was sent for pathological evaluation.

Results: Endoscopic revision DCR was performed on 50 failed external DCR subjects with one-year follow-up. Of these, 31 were female (62%). The age range of the subjects was 18-88 years (mean: 59.98 years). Sinus CT showed at least one abnormality in 94% of cases. Revision endoscopy showed septal deviation (66%), scar formation (32%), ostium problems (28%), and sump syndrome (6%). Pathologic and clinical findings showed that chronic inflammation had a significant association with scar tissue and septal synechia (P = 0.001 and 0.008, respectively). At the final follow-up, anatomical and functional success was achieved in 45 out of 50 (90%) of subjects.

Conclusion: Endoscopic revision DCR when performed as cooperation of otolaryngologists and ophthalmologists may help resolve the endonasal problems and increase the success rate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5000531PMC
http://dx.doi.org/10.4103/2008-322X.188396DOI Listing

Publication Analysis

Top Keywords

failed external
16
teamwork revision
8
revision endoscopic
8
performed failed
8
external dcr
8
dcr subjects
8
endoscopic revision
8
revision dcr
8
dcr performed
8
revision
6

Similar Publications

Purpose: To evaluate the healing of meniscal repair performed concomitantly with anterior cruciate ligament reconstruction (ACLR) using second-look arthroscopy, and the relationship between meniscal healing and knee laxity using quantitative evaluation under anesthesia.

Methods: This retrospective study included patients who underwent primary double-bundle ACLR with meniscal repair between June 2016 and June 2021, with a two-year minimum follow-up. Meniscal healing was evaluated by second-look arthroscopy at least one year postoperatively, and knee laxity was measured under general anesthesia preoperatively, intraoperatively, and at second-look.

View Article and Find Full Text PDF

Objective: To determine whether patients undergoing a trial of labor with a breech presentation following a failed attempt of external cephalic version (ECV) are at increased risk of adverse maternal and neonatal outcomes.

Methods: This retrospective cohort study was conducted at a single university-affiliated medical center. The study group comprised women with singleton pregnancies at term, categorized into three groups: those who underwent a failed external cephalic version (ECV) and subsequently attempted a trial of breech delivery (Breech-failed-ECV group), those who attempted an assisted vaginal breech delivery without a prior ECV attempt (Breech-no-ECV group), and those with vertex presentation following a successful ECV (Vertex-ECV).

View Article and Find Full Text PDF

Using an interatomic potential that can capture the tetrahedral configuration of water molecules (HO) in ice without the need to explicitly track the motion of the O and H atoms, coarse-grained (CG) atomistic simulations are performed here to characterize the structures, energy, cohesive strengths, and fracture resistance of the grain boundaries (GBs) in polycrystalline ice resulting from water freezing. Taking the symmetric tilt grain boundaries (STGBs) with a tilting axis of ⟨0001⟩ as an example, several main findings from our simulations are (i) the GB energy, , exhibits a strong dependence on the GB misorientation angle, θ. The classical Read-Shockley model only predicts the - θ relation reasonably well when θ < 20° or θ > 45° but fails when 20° < θ < 45°; (ii) two "valleys" appear in the -θ landscape.

View Article and Find Full Text PDF

3D-printed suction clamps for tensile testing of brain tissue.

J Mech Behav Biomed Mater

December 2024

Department of Oral Rehabilitation, University of Otago, 310 Great King Street North, Dunedin, New Zealand.

The conventional mounting of ultra-soft biological tissues often involves gluing it between two plates or manually tightening grips. Both methods demand delicate handling skills and are time-consuming. This study outlines the design and practical application of 3D-printed suction clamps for uniaxial tension tests on brain samples.

View Article and Find Full Text PDF

This study addresses a critical gap in the existing literature on carbon dioxide and ionic liquid (IL) mixtures, where fragmented and incomplete data, particularly for flow properties, hinder practical applications. Therefore, this work aimed to establish a robust and efficient method for predicting the density of the CO-IL mixtures across diverse operating conditions and IL families using novel validation techniques. Both linear and symbolic regression models provided relevant insights but failed to accurately capture the IL-CO interactions in a mixture that determine the molar volume of CO at infinite dilution when solubilized by a given IL.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!