A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

How accurately and consistently do laboratories measure workplace concentrations of respirable crystalline silica? | LitMetric

How accurately and consistently do laboratories measure workplace concentrations of respirable crystalline silica?

Regul Toxicol Pharmacol

Cox Associates, 503 Franklin St., Denver, CO 80218, United States. Electronic address:

Published: November 2016

Permissible exposure limits (PELs) for respirable crystalline silica (RCS) have recently been reduced from 0.10 to 0.05 mg/m. This raises an important question: do current laboratory practices and standards for assessing RCS concentrations permit reliable discrimination between workplaces that are in compliance and workplaces that are not? To find out, this paper examines recent laboratory performance in quantifying RCS amounts on filters sent to them to assess their proficiency. A key finding is that accredited laboratories do not reliably (e.g., with 95% confidence) estimate RCS quantities to within a factor of 2. Thus, laboratory findings indicating that RCS levels are above or below a PEL provide little confidence that this is true. The current accreditation standard only requires laboratories to achieve estimates within three standard deviations of the correct (reference) value at least two thirds of the time, rather than a more usual standard such as within 25% of the correct value at least 95% of the time. Laboratory practices may improve as the new PEL is implemented, but they are presently essentially powerless to discriminate among RCS levels over most of the range of values that have been tested, leaving employers and regulators without a reliable means to ascertain when workplace RCS levels are above or below the PEL.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.yrtph.2016.09.008DOI Listing

Publication Analysis

Top Keywords

rcs levels
12
respirable crystalline
8
laboratory practices
8
levels pel
8
rcs
7
accurately consistently
4
consistently laboratories
4
laboratories measure
4
measure workplace
4
workplace concentrations
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!