The aim of this study is to determine the intra- and intersession reliability of nonnormalized surface electromyography (sEMG) on the muscles actuating the forearm during maximum voluntary isometric contractions (MVIC). A subobjective of this study is to determine the intra- and intersession reliability of forearm MVIC force or torque, which is a prerequisite to assess sEMG reliability. Eighteen healthy adults participated at 4 different times: baseline, 1-h post, 6-h post, and 24-h post. They performed 3 MVIC trials of forearm flexion, extension, pronation, and supination. sEMG of the biceps brachii short head, brachialis, brachioradialis, triceps brachii long head, pronator teres, and pronator quadratus were measured. The intraclass correlation coefficient (ICC) on MVIC ranged from 0.36 to 0.99. Reliability was excellent for flexion, extension, and supination MVIC for both intra- and intersession. The ICC on sEMG ranged from 0.58 to 0.99. sEMG reliability was excellent for brachialis, brachioradialis, and pronator quadratus, and good to excellent for triceps brachii, biceps brachii, and pronator teres. This study shows that performing 3 MVICs is sufficient to obtain highly reliable maximal sEMG over 24 h for the main muscles actuating the forearm. These results confirm the potential of sEMG for muscle motor functional monitoring.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1123/jab.2015-0214 | DOI Listing |
Psychiatry Res
February 2025
Black Dog Institute, Sydney, Australia; Discipline of Psychiatry and Mental Health, School of Clinical Medicine, University of New South Wales, Australia; The George Institute for Global Health, Sydney, Australia.
Background: Ketamine and its derivates (e.g. esketamine) are increasingly used in clinical settings for treatment-resistant depression (TRD).
View Article and Find Full Text PDFExp Physiol
December 2024
Department of Sport and Exercise Sciences, Manchester Metropolitan University Institute of Sport, Manchester, UK.
Using proton magnetic resonance spectroscopy (H MRS) to determine total creatine (tCr) concentrations will become increasingly prevalent, as the role of creatine (Cr) in supporting brain health gains interest. Methodological limitations and margins of error in repeated H MRS, which often surpass reported effects of supplementation, permeate existing literature. We examined the intra- and inter-session reliability and repeatability of H MRS for determining tCr concentrations across multiple brain regions (midbrain, visual cortex and frontal cortex).
View Article and Find Full Text PDFKlin Monbl Augenheilkd
December 2024
Ophthalmology, Department of Ophthalmology & Visual Sciences, University of Iowa Health Care, Iowa City, IA, United States.
Background: Peripapillary blood flow is of diagnostic value in glaucoma.
Material And Methods: We investigated the reproducibility of peripapillary blood flow measurements in healthy individuals and in open-angle glaucoma (OAG) patients with the Nidek laser speckle flowgraphy (LSFG)-NAVI system. Blood flow was calculated as the mean of vascular area (MV), mean of tissue area (MT), and mean of overall flow (MA).
Retina
December 2024
Harvard Retinal Imaging Lab, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
Purpose: To assess repeatability of macular inner choroid flow deficit percentage (ICFD%) in intermediate age-related macular degeneration (iAMD) and controls employing various post-processing approaches.
Methods: Cross-sectional, observational study. We included (1) 22 iAMD and 24 control eyes, with (2) age >50 years, (3) visual acuity >20/32, and (4) no additional ocular and systemic confounders.
J Musculoskelet Neuronal Interact
December 2024
Department of Physical Education and Sport, Faculty of Sports Sciences and Physical Education, University of A Coruña, A Coruña, Spain.
Objectives: The synergy between arm and shoulder muscles, along with isometric finger flexor strength, are crucial for climbing proficiency. However, tests often assess these factors separately rather than in a unified action. This study aimed to determine the intra- and inter-session reliability of the mean propulsive velocity (MPV) during pull-ups on a large hold and on small climbing edges.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!