A positively charged tetraphenylethene (TPE) derivative, TPE-4MN, was synthesized as a probe for heparin based on aggregation induced emission. On the addition of 5.0 μg/mL of heparin, TPE-4MN showed an enhanced emission of about 10-fold. The change in fluorescence at 475 nm was linear over a range of heparin concentrations of 0-1.0 μg/mL with an R = 0.99988 and the limit of detection (LOD) was calculated to be 0.75 μg/mL. The mechanism of the detection was proven to be through an ion pairing interaction. TPE-4MN showed good selectivity for heparin over other types of polysaccharides and could easily distinguish heparin from heparan sulfate, a glycosaminoglycan having a similar structure to that of heparin.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ab.2016.09.007 | DOI Listing |
Biomimetics (Basel)
December 2024
Institute for Macromolecular Chemistry, Stefan-Meier-Strasse 31, 79104 Freiburg, Germany.
Cardiovascular diseases such as myocardial infarction or limb ischemia are characterized by regression of blood vessels. Local delivery of growth factors (GFs) involved in angiogenesis such as fibroblast blast growth factor-2 (FGF-2) has been shown to trigger collateral neovasculature and might lead to a therapeutic strategy. In vivo, heparin, a sulfated polysaccharide present in abundance in the extracellular matrix (ECM), has been shown to function as a local reservoir for FGF-2 by binding FGF-2 and other morphogens and it plays a role in the evolution of GF gradients.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
College of Chemistry, Henan Joint International Research Laboratory of Green Construction of Functional Molecules and Their Bioanalytical Applications, Food Laboratory of Zhongyuan, Zhengzhou University, Zhengzhou, 450001, China.
Background: Heparin is a widely used anticoagulant in clinic. However, improper dosing can increase the risk of thromboembolic events, potentially leading to life-threatening complications. Clinic monitoring of heparin is very important for its use safety.
View Article and Find Full Text PDFChem Commun (Camb)
January 2025
Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610064, China.
Heparin is a widely used blood anticoagulant and its monitoring in blood is essential during surgery. Unavoidable interference factors such as blood color and luminescence can interfere with the fluorescence visualization of heparin. Herein, we found a ratiometric fluorescence probe consisting of SYBR green and cresyl violet responsive to heparin mainly based on electrostatic interactions.
View Article and Find Full Text PDFLangmuir
December 2024
College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, PR China.
Heparin is widely used to treat thrombosis because it is an effective anticoagulant. However, excessive use of heparin can lead to an increased risk of bleeding, which makes the quantitative detection of heparin very important. An amphiphilic perylene bisimide molecule (denoted PBI-9) was developed, which presented a near-infrared emission peak at 730 nm when it was aggregated.
View Article and Find Full Text PDFFront Cell Infect Microbiol
November 2024
Department of Critical Care Medicine, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Background: The accurate and sensitive diagnosis of intracranial infection continues to pose a critical challenge. This study aimed to probe into the clinical value of heparin binding protein (HBP) in bacterial intracranial infection.
Methods: Patients suspected of having bacterial intracranial infection and admitted to Shanghai General Hospital from November 2021 to November 2023 were selected as study subjects and divided into an infected group and a non-infected group.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!