Background: Some but not all prior studies have shown that women receiving a primary prophylactic implantable cardioverter defibrillator (ICD) have a lower risk of death and appropriate shocks than men.

Purpose: To evaluate the effect of gender on the risk of appropriate shock, all-cause mortality and inappropriate shock in contemporary studies of patients receiving a primary prophylactic ICD.

Data Source: PubMed, LIVIVO, Cochrane CENTRAL between 2010 and 2016.

Study Selection: Studies providing at least 1 gender-specific risk estimate for the outcomes of interest.

Data Extraction: Abstracts were screened independently for potentially eligible studies for inclusion. Thereby each abstract was reviewed by at least two authors.

Data Synthesis: Out of 680 abstracts retained by our search strategy, 20 studies including 46'657 patients had gender-specific information on at least one of the relevant endpoints. Mean age across the individual studies varied between 58 and 69 years. The proportion of women enrolled ranged from 10% to 30%. Across 6 available studies, women had a significantly lower risk of first appropriate shock compared with men (pooled multivariable adjusted hazard ratio 0.62 (95% CI [0.44; 0.88]). Across 14 studies reporting multivariable adjusted gender-specific hazard ratio estimates for all-cause mortality, women had a lower risk of death than men (pooled hazard ratio 0.75 (95% CI [0.66; 0.86]). There was no statistically significant difference for the incidence of first inappropriate shocks (3 studies, pooled hazard ratio 0.99 (95% CI [0.56; 1.73]).

Limitations: Individual patient data were not available for most studies.

Conclusion: In this large contemporary meta-analysis, women had a significantly lower risk of appropriate shocks and death than men, but a similar risk of inappropriate shocks. These data may help to select patients who benefit from primary prophylactic ICD implantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5019464PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0162756PLOS

Publication Analysis

Top Keywords

primary prophylactic
16
lower risk
16
hazard ratio
16
appropriate shocks
12
risk appropriate
12
women lower
12
studies
9
prophylactic implantable
8
studies women
8
receiving primary
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!