[Are the cobalt hip prosthesis dangerous?].

Med Sci (Paris)

Service de toxicologie clinique, médico-légale, de l'environnement et en entreprise, CHU Sart-Tilman, 1 avenue de l'Hôpital, 4000 Liège, Belgique.

Published: August 2017

The placement of a hip prosthesis is one of the most common orthopedic surgical procedures. Some implants contain metal and are therefore capable of releasing metal particles like cobalt in patients who wear metal prostheses. Cobalt can be responsible of local toxicity (including metallosis, hypersensitivity reaction, and benign tumor) or systemic toxicity (including cardiomyopathy, polycythemia, hypothyroidism, and neurological disorders). To monitor potential toxicity of metal hip prostheses, an annual monitoring of patients implanted is recommended and includes clinical examination, radiological examination and blood cobalt determination. The cobalt concentration in blood allows to estimate the risk of toxicity and to evaluate the performance of the implant. The currently recommended threshold value is equal to 7 µg of cobalt per liter of blood. Our study, conducted on 251 patients over a period of 4 years, has shown that the cobalt concentration average was 2.51 µg/l in blood, with 51 patients having a cobaltemia higher than the threshold of 7 µg/l.

Download full-text PDF

Source
http://dx.doi.org/10.1051/medsci/20163208021DOI Listing

Publication Analysis

Top Keywords

hip prosthesis
8
toxicity including
8
cobalt concentration
8
cobalt
6
[are cobalt
4
cobalt hip
4
prosthesis dangerous?]
4
dangerous?] placement
4
placement hip
4
prosthesis common
4

Similar Publications

Bone marrow edema (BME), a notable manifestation during the progression of osteonecrosis of the femoral head (ONFH), exhibits significant associations with femoral head collapse, pain, and prognosis, howeverits' pathogenesis remains underexplored. In this study, specimens from patients undergoing total hip arthroplasty (THA) were analyzed. The results revealed significantly higher Visual Analog Scale (VAS) scores and CT low-density area ratio in the BME group compared to the control group.

View Article and Find Full Text PDF

Background: Increasing evidence shows that postoperative innate immune dysregulation is associated with delayed recovery and infectious complications. The aim of this study was to compare the effects of general versus spinal anesthesia on innate immune function during and after total hip arthroplasty (THA).

Methods: This comparative matched cohort study used data from two single-center randomized-controlled trials.

View Article and Find Full Text PDF

Introduction: The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup made of vitamin E blended highly cross-linked polyethylene. We addressed the following questions: (1) What are the clinical and (2) radiographic outcomes 10 years after implantation? (3) What is the revision rate?

Methods: In this prospective observational study in a tertiary care centre we investigated all consecutive cases of total hip replacement with the RM Pressfit vitamys cup between September 2009 and November 2011. It was implanted in 162 hips, 49.

View Article and Find Full Text PDF

Introduction: A primary objective when performing a total hip arthroplasty (THA) is to restore hip biomechanics in accordance with a chosen surgical plan. The aim of this study was to assess the accuracy of a 3D-printed patient-specific guide for delivering a planned femoral osteotomy for both a posterior and an anterior approach.

Methodology: 40 patients (20 anterior and 20 posterior) scheduled for THA received a preoperative work-up allowing for patient-specific implant sizing and positioning.

View Article and Find Full Text PDF

Avascular necrosis (AVN) of the hip, a rare cause of pelvic pain in the third trimester of pregnancy, often presents with nonspecific symptoms that resemble common musculoskeletal conditions. This ambiguity, coupled with concerns about the safety of magnetic resonance imaging (MRI) during pregnancy, can hinder timely diagnosis. We report a unique case of a 32-year-old primigravida diagnosed with a hip fracture and bilateral AVN of the femoral head in the immediate postpartum period, a complication seemingly not previously documented in pregnant patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!