Integrated Myocardial Perfusion Imaging Diagnostics Improve Detection of Functionally Significant Coronary Artery Stenosis by 13N-ammonia Positron Emission Tomography.

Circ Cardiovasc Imaging

From the Division of Cardiology, Department of Internal Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea (J.M.L.); Department of Internal Medicine, Cardiovascular Center (C.H.K., B.-K.K., D.H., J.P., J.Z., Y.T., H.-S.K.), Department of Nuclear Medicine (J.-I.B., M.S., J.C.P., G.J.C.), and Department of Internal Medicine, Emergency Medical Center (S.-H.N.), Seoul National University Hospital, Korea; Institute of Aging, Seoul National University, Korea (B.-K.K., S.-H.N.); Department of Internal Medicine, Sejong General Hospital, Bucheon, Korea (K.-H.J.); and Department of Cardiology, Heart Institute, Center for Medical Research and Information, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea (J.-M.A., S.-J.P.).

Published: September 2016

Background: Recent evidence suggests that the diagnostic accuracy of myocardial perfusion imaging is improved by quantifying stress myocardial blood flow (MBF) in absolute terms. We evaluated a comprehensive quantitative (13)N-ammonia positron emission tomography ((13)NH3-PET) diagnostic panel, including stress MBF, coronary flow reserve (CFR), and relative flow reserve (RFR) in conjunction with relative perfusion defect (PD) assessments to better detect functionally significant coronary artery stenosis.

Methods And Results: A total of 130 patients (307 vessels) with coronary artery disease underwent both (13)NH3-PET and invasive coronary angiography with fractional flow reserve (FFR) measurement. Diagnostic accuracy, optimal cut points, and discrimination indices of respective (13)NH3-PET quantitative measures were compared, with FFR as standard reference. The capacity to discern disease with stepwise addition of stress MBF, CFR, and RFR to qualitatively assessed relative PD was also gauged, using the category-free net reclassification index. All quantitative measures showed significant correlation with FFR (PET-derived CFR, r=0.388; stress MBF, r=0.496; and RFR, r=0.780; all P<0.001). Optimal respective cut points for FFR ≤0.8 and ≤0.75 were 1.99 and 1.84 mL/min per g for stress MBF and 2.12 and 2.00 for PET-derived CFR. Discrimination indices of quantitative measures that correlated with FFR ≤0.8 were all significantly higher than that of relative PD (area under the curve: 0.626, 0.730, 0.806, and 0.897 for relative PD, CFR, stress MBF, and RFR, respectively; overall comparison P<0.001). The capacity for functionally significant coronary stenosis was incrementally improved by the successive addition of CFR (net reclassification index=0.629), stress MBF (net reclassification index=0.950), and RFR (net reclassification index=1.253; all P<0.001) to relative PD.

Conclusions: Integrating quantitative (13)NH3-PET measures with qualitative myocardial perfusion assessment provides superior diagnostic accuracy and improves the capacity to detect functionally significant coronary artery stenosis.

Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01621438 and NCT01366404.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCIMAGING.116.004768DOI Listing

Publication Analysis

Top Keywords

coronary artery
12
stress mbf
12
flow reserve
12
myocardial perfusion
8
perfusion imaging
8
functionally coronary
8
13n-ammonia positron
8
positron emission
8
emission tomography
8
diagnostic accuracy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!