A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Early experience with the Penumbra SMART coil in the endovascular treatment of intracranial aneurysms: Safety and efficacy. | LitMetric

Background: Penumbra SMART coils differ from traditional microcoils used for endovascular coil embolization of intracranial aneurysms (IAs) in that they (1) become progressively softer from their distal to proximal end, rather than being of uniform stiffness, (2) have a tight conformational structure, and (3) have a more robust stretch-resistance platform. These properties aid in preventing microcatheter prolapse and coil herniation during coil deployment and in filling small pockets of the aneurysm sac.

Objective/methods: To determine the safety and efficacy of this device, the records of 17 consecutive patients with IAs treated with SMART coils were retrospectively analyzed.

Results: Thirteen female and four male patients were identified. Eleven patients presented with subarachnoid hemorrhage, four had recurrent aneurysms, and two had incidentally discovered aneurysms. Twelve aneurysms (two of which were recurrent) were treated with stand-alone coiling, three were treated with stent-assisted coiling, and two with flow diversion with adjuvant coiling. Microcatheter prolapse occurred in one case of a recurrent aneurysm, due to mechanical limitations imposed by a stent placed during prior coiling. Raymond-Roy Occlusion Classification (RROC) I or II occlusion was achieved in 12 aneurysms, including all 10 undergoing primary stand-alone coiling. Of the five RROC III occlusions, two were expected given treatment with flow diversion, while the other three occurred in complex, recurrent aneurysms. One patient suffered a thromboembolic complication of unclear clinical significance.

Conclusions: The Penumbra SMART coil is a safe and effective device for the endovascular treatment of IAs. Follow-up studies are required to establish long-term results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5564367PMC
http://dx.doi.org/10.1177/1591019916663479DOI Listing

Publication Analysis

Top Keywords

penumbra smart
12
smart coil
8
endovascular treatment
8
intracranial aneurysms
8
safety efficacy
8
smart coils
8
microcatheter prolapse
8
recurrent aneurysms
8
stand-alone coiling
8
flow diversion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!