Background: Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices.
Objectives: This study sought to evaluate the clinical outcomes of TAVR for bicuspid AS with early- and new-generation devices.
Methods: The Bicuspid TAVR Registry is an international multicenter study enrolling consecutive patients with bicuspid AS undergoing TAVR between April 2005 and May 2015.
Results: Of 301 patients, 199 patients (71.1%) were treated with early-generation devices (Sapien XT [Edwards Lifesciences Corporation, Irvine, California]: n = 87; CoreValve [Medtronic, Minneapolis, Minnesota]: n = 112) and 102 with new-generation devices (Sapien 3 [Edwards Lifesciences Corporation]: n = 91; Lotus [Boston Scientific Corporation, Marlborough, Massachusetts]: n = 11). The mean Society of Thoracic Surgeons score was 4.7 ± 5.2 without significant differences between groups (4.6 ± 5.1 vs. 4.9 ± 5.4; p = 0.57). Overall, all-cause mortality rates were 4.3% at 30 days and 14.4% at 1 year. Moderate or severe paravalvular leak was absent and significantly less frequent with new-generation compared to early-generation devices (0.0% vs. 8.5%; p = 0.002), which resulted in a higher device success rate (92.2% vs. 80.9%; p = 0.01). There were no differences between early- and new-generation devices in stroke (2.5% vs. 2.0%; p > 0.99), life-threatening bleeding (3.5% vs. 2.9%; p > 0.99), major vascular complication (4.5% vs. 2.9%; p = 0.76), stage 2 to 3 acute kidney injury (2.5% vs. 2.9%; p > 0.99), early safety endpoints (15.1% vs. 10.8%; p = 0.30), and 30-day all-cause mortality (4.5% vs. 3.9%; p > 0.99).
Conclusions: The clinical outcomes of TAVR in patients with bicuspid AS were favorable. New-generation devices were associated with less paravalvular leak and, hence, a higher device success rate than early-generation devices. (The Bicuspid Aortic Stenosis Following Transcatheter Aortic Valve Replacement Registry [Bicuspid TAVR]; NCT02394184).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2016.06.041 | DOI Listing |
BMC Cardiovasc Disord
January 2025
Graduate School of Public Health, St Luke's International University, Tokyo, Japan.
Background: Recent studies revealed an association between small kidney volume and progression of kidney dysfunction in particular settings such as kidney transplantation and transcatheter aortic valve implantation. We hypothesized that kidney volume was associated with the incidence of kidney-related adverse outcomes such as worsening renal function (WRF) in patients with acute heart failure (AHF).
Methods: This study was a single-center retrospective cohort study.
Mol Diagn Ther
January 2025
Department of Medicine and Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, 4288A-1151 Richmond Street North, London, ON, N6A 5B7, Canada.
Clinical endpoints caused by hyperlipoproteinemia include atherosclerotic cardiovascular disease and acute pancreatitis. Emerging lipid-lowering therapies targeting proprotein convertase subtilisin/kexin 9 (PCSK9), lipoprotein(a), apolipoprotein C-III, and angiopoietin-like protein 3 represent promising advances in the management of patients with hyperlipoproteinemia. These therapies offer novel approaches for lowering pathogenic lipid and lipoprotein species, particularly in patients with serious perturbations who are not adequately controlled with conventional treatments or who are unable to tolerate them.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.
Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).
Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).
Eur J Cardiothorac Surg
January 2025
Department of Cardiac Surgery, University Hospital Quironsalud Madrid, Spain.
Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!