Conclusions: Sensorineural hearing loss must be considered within the clinical picture of systemic lupus erythematosus. The results confirm the usefulness of extended high-frequency audiometry in the audiologic testing of these patients, enabling the possibility of modifying or applying a preventive treatment for a possible hearing loss.

Objectives: Hearing involvement is usually under-diagnosed with routine auditory examination. This study proposes the use of extended high-frequency audiometry to achieve a correct detection of a possible asymptomatic hypoacusis in early stages of the disease. The aim of this study is to analyze the hearing levels in extended high-frequencies in these patients and to correlate the hearing loss with the severity of the disease and the immunological parameters.

Methods: A descriptive cross-sectional study was performed. Fifty-five patients with systemic lupus erythematosus were included in the study. The control group consisted of 71 patients paired by age and sex with the study population. Both a pure tone audiometry and an extended high-frequency audiometry (8-18 KHz) were performed.

Results: In total, 70% were diagnosed with sensorineural hearing loss with extended high-frequency audiometry, overcoming the results obtained with pure tone audiometry (30.9%). Statistically significant correlations were found within the patients regarding sensorineural hearing loss related with age, disease activity and cryoglobulinemia.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00016489.2016.1219049DOI Listing

Publication Analysis

Top Keywords

hearing loss
16
extended high-frequency
16
high-frequency audiometry
16
systemic lupus
12
lupus erythematosus
12
sensorineural hearing
12
hearing
8
pure tone
8
tone audiometry
8
audiometry
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!