Focal-plane arrays (FPAs) are often interfered by heavy fixed-pattern noise, which severely degrades the detection rate and increases the false alarms in airborne point target detection systems. Thus, high-precision nonuniformity correction is an essential preprocessing step. In this paper, a new nonuniformity correction method is proposed based on a staircase scene. This correction method can compensate for the nonlinear response of the detector and calibrate the entire optical system with computational efficiency and implementation simplicity. Then, a proof-of-concept point target detection system is established with a long-wave Sofradir FPA. Finally, the local standard deviation of the corrected image and the signal-to-clutter ratio of the Airy disk of a Boeing B738 are measured to evaluate the performance of the proposed nonuniformity correction method. Our experimental results demonstrate that the proposed correction method achieves high-quality corrections.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.55.007149DOI Listing

Publication Analysis

Top Keywords

nonuniformity correction
16
correction method
16
point target
12
target detection
12
detection systems
8
correction
6
staircase-scene-based nonuniformity
4
correction aerial
4
aerial point
4
detection
4

Similar Publications

Accuracies of measuring the artifact index (AI), a quantitative artifact evaluation index in X-ray CT images, were investigated. The AI is calculated based not only on the standard deviation (SD) of the artifact area in the image, but also on the SD of noise components for considering the noise influence. However, conventional measurement methods may not follow this consideration, for example the non-uniformity of the noise distribution is not taken into account, resulting in reducing the accuracy of AI.

View Article and Find Full Text PDF

Enhancing the optoelectronic properties of SnS mixed-phase heterostructure engineering.

Nanoscale

December 2024

Optoelectronics and Photonics Laboratory, Department of Physics, Tezpur University, Napaam 784028, Assam, India.

SnS holds great promise in optoelectronics, especially in photovoltaic devices, due to its exceptional intrinsic electronic properties and optimal optical absorption. However, its prospective applications are often limited by structural instability or oxidation, leading to internal or external defect states. This study proposes a mixed-phase SnS/h-BN heterostructure to enhance chemical and thermal stability while preserving the intrinsic optoelectronic properties of SnS.

View Article and Find Full Text PDF

Background: The clinical use of flattening filter free (FFF) radiotherapy has significantly increased in recent years due to its effective enhancement of dose rates and reduction of scatter dose. A proposal has been made to adjust the incident electron angle of the accelerator to expand the application of FFF beams in areas such as large planning target volumes (PTVs). However, the inherent softening characteristics and non-uniformity of lateral dose distribution in FFF beams inevitably lead to increased dosimetry errors, especially for ionization chambers widely used in clinical practice, which may result in serious accidents during FFF radiotherapy.

View Article and Find Full Text PDF

Model-based CBCT scatter correction with dual-layer flat-panel detector.

Med Phys

December 2024

Research Center for Advanced Detection Materials and Medical Imaging Devices, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.

Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (CBCT) imaging has been increasing. However, the image quality of dual-energy CBCT remains constrained by the Compton scattered x-ray photons.

Purpose: The objective of this study is to develop a novel scatter correction method, named e-Grid, for DL-FPD based CBCT imaging.

View Article and Find Full Text PDF

Unsupervised Bayesian generation of synthetic CT from CBCT using patient-specific score-based prior.

Med Phys

December 2024

Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA.

Article Synopsis
  • CBCT scans are crucial for patient alignment in radiotherapy, but their image quality is often compromised by artifacts and inaccurate Hounsfield unit values, limiting their quantitative applications.
  • The study introduces an unsupervised learning approach utilizing a patient-specific diffusion model to generate synthetic CT images from CBCT, improving image quality for adaptive radiotherapy.
  • Results demonstrated that this method effectively reduced artifacts in CBCT images from various cancer types, enhancing the potential for better clinical outcomes in radiotherapy.