A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Compatibility of Meropenem with Different Commercial Peritoneal Dialysis Solutions. | LitMetric

Compatibility of Meropenem with Different Commercial Peritoneal Dialysis Solutions.

Perit Dial Int

Department of Internal Medicine I, Division of Infectious Diseases and Tropical Medicine, Medical University Vienna, Vienna, Austria.

Published: December 2017

♦ BACKGROUND: Intraperitoneal administration of antimicrobial agents is recommended for the treatment of peritoneal dialysis (PD)-related peritonitis. For home-based antimicrobial therapy it is common to supply patients with PD fluid bags with admixed antibiotic. Thus, the compatibility of meropenem with different PD fluids (PDFs), namely Extraneal, Physioneal 1.36% and Physioneal 2.27% (all Baxter Healthcare Corp., Deerfield, IL, USA), was investigated under varying storage conditions. ♦ METHODS: Meropenem (Venus Pharma, Werne, Germany) was stored at 6°C and 25°C over 14 days and at 37°C over 24 hours. Drug concentration over time was determined using high performance liquid chromatography, drug activity by a diffusion disk method, diluent stability by visual inspection and drug adsorption was calculated. Blank PD fluids and deionized water were used as comparator solutions. ♦ RESULTS: Compared to water, the stability of meropenem was minimally lower in Extraneal but markedly reduced in both Physioneal solutions. No significant drug adsorption was detected for any PDF investigated. ♦ CONCLUSIONS: Meropenem is stable and compatible with Extraneal and might be stored for up to a week at refrigeration temperature (6°C). A loss of ~20% of meropenem after 2 days at room temperature should be considered. Mixed Physioneal appears not suitable for storage at any temperature after meropenem has been admixed. A considerable drug degradation due to the warming up to body temperature through heating plates should further be taken into account in clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.3747/pdi.2016.00018DOI Listing

Publication Analysis

Top Keywords

compatibility meropenem
8
peritoneal dialysis
8
solutions ♦
8
drug adsorption
8
meropenem
6
drug
5
meropenem commercial
4
commercial peritoneal
4
dialysis solutions
4
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!