Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
♦ BACKGROUND: Intraperitoneal administration of antimicrobial agents is recommended for the treatment of peritoneal dialysis (PD)-related peritonitis. For home-based antimicrobial therapy it is common to supply patients with PD fluid bags with admixed antibiotic. Thus, the compatibility of meropenem with different PD fluids (PDFs), namely Extraneal, Physioneal 1.36% and Physioneal 2.27% (all Baxter Healthcare Corp., Deerfield, IL, USA), was investigated under varying storage conditions. ♦ METHODS: Meropenem (Venus Pharma, Werne, Germany) was stored at 6°C and 25°C over 14 days and at 37°C over 24 hours. Drug concentration over time was determined using high performance liquid chromatography, drug activity by a diffusion disk method, diluent stability by visual inspection and drug adsorption was calculated. Blank PD fluids and deionized water were used as comparator solutions. ♦ RESULTS: Compared to water, the stability of meropenem was minimally lower in Extraneal but markedly reduced in both Physioneal solutions. No significant drug adsorption was detected for any PDF investigated. ♦ CONCLUSIONS: Meropenem is stable and compatible with Extraneal and might be stored for up to a week at refrigeration temperature (6°C). A loss of ~20% of meropenem after 2 days at room temperature should be considered. Mixed Physioneal appears not suitable for storage at any temperature after meropenem has been admixed. A considerable drug degradation due to the warming up to body temperature through heating plates should further be taken into account in clinical practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3747/pdi.2016.00018 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!