A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c). | LitMetric

Background: To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia.

Methods: This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c intraocular lenses. We quantitatively assessed the postoperative values of vault and pupil size at 1 day, 1 week, and 1 month following implantation using a rotating Scheimpflug camera (Pentacam). We compared these postoperative values within and between the two groups and identified the factors affecting vault change.

Results: The mean vaults at 1 day, 1 week, and 1 month following ICL V4 implantation were 303.68 ± 185.11, 517.89 ± 160.07 and 521.32 ± 155.72 μm respectively, and those following ICL V4c were 316.67 ± 186.89, 495.13 ± 180.84 and 510.77 ± 175.51 μm, respectively. There was a significant difference in vault between 1 day and 1 week postoperatively. There was a significant association between the vault change and the pupil size change in both groups from 1 day to 1 month postoperatively (Pearman correlation coefficient; ICL V4: r = 0.585, P = 0.001; ICL V4c: r = 0.588, P <0.001). The vault value 1 month after implantation of ICL V4 and ICL V4c was associated with the preoperative anterior chamber depth, horizontal corneal diameter, horizontal and vertical sulcus-to-sulcus.

Conclusions: Pupil movement is a critical factor in vault change, with increasing vault observed postoperatively from 1 day to 1 week associated with the declining effects of pharmacological miosis and increasing pupil size. The anterior chamber depth, horizontal corneal diameter, horizontal and vertical sulcus-to-sulcus show some correlation with vault.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5015244PMC
http://dx.doi.org/10.1186/s12886-016-0336-8DOI Listing

Publication Analysis

Top Keywords

icl v4c
20
factors vault
12
1 day 1 week
12
icl
10
early changes
8
implantable collamer
8
collamer lens
8
central hole
8
icl icl
8
vault change
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!