The present study reports the use of a phakic toric Implantable Collamer Lens (ICL) that improved the refraction correction of high myopia and astigmatism in a case of keratectasia following corneal cross-linking. A 31-year-old male was diagnosed with keratectasia 12 years after laser-assisted keratomileusis (LASIK). Following LASIK, the manifest refraction was -3.50-2.25×90 [0.1 logarithmic expression (LogMAR) best corrected visual acuity (BVCA)] in the right eye and -8.00-3.50×175 (0.3 LogMAR BCVA) in the left eye, with a LogMAR uncorrected distance visual acuity (UDVA) of 0.8 and a 'counting fingers' value of 3 ft (CF @3 ft) in the left and right eyes, respectively. Riboflavin/ultraviolet A light (UVA) corneal crosslinking (CXL) was conducted on both eyes. Seven months after cross-linking, LogMAR UDVA was 0.4, the manifest refraction was -2.75-2.50×85 and LogMAR BCVA was 0.1 in the right eye. In the left eye, LogMAR UDVA was CF @3 ft, the manifest refraction was -15.00 and LogMAR BCVA was 0.3. The corneal topography was stable 7 months after CXL. Phakic toric ICL was implanted to correct the refractive error, following which the LogMAR UDVA improved to 0.1 in the right eye and 0.3 in left eye, and visual acuity remained stable for 6 months after ICL implantation. In conclusion, combining riboflavin/UVA corneal cross-linking and phakic toric ICL implantation may be an alternative in the correction of high refractive error in patients with keratectasia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4998209PMC
http://dx.doi.org/10.3892/etm.2016.3481DOI Listing

Publication Analysis

Top Keywords

phakic toric
16
manifest refraction
12
visual acuity
12
logmar bcva
12
left eye
12
logmar udva
12
corneal crosslinking
8
toric implantable
8
implantable collamer
8
correction high
8

Similar Publications

Purpose: To explore the significance of changes in anterior chamber depth (ΔACD) and astigmatism between 4 and 8 weeks following uneventful phacoemulsification.

Patients And Methods: Anterior chamber depth (ACD, mm), autorefractometry and subjective refraction were monitored in pseudophakic eyes implanted with non-toric IOLs (group 1, SA60AT, n=36; group 2, SN60WF, n=34; group 3, ICBOO, n=16) and phakic control group (n=30, group 4a, for ACD and autorefractometry) over four weeks. Changes in subjective refractions were compared with repeatability in normal phakic eyes (n=30, group 4b).

View Article and Find Full Text PDF

Purpose: To compare 6-month visual outcomes and optical quality after small incision lenticule extraction (SMILE) and toric Implantable Collamer Lens (ICL) (STAAR Surgical Company) implantation for high myopia astigmatism.

Methods: This was a prospective non-randomized study. Overall, 88 eyes of 88 patients with high astigmatism (≥ 2.

View Article and Find Full Text PDF

Background: Astigmatism is the most prevalent refractive error among children and adults, and it can lead to visual impairment if left uncorrected. The management of compound hyperopic astigmatism is more challenging. This study presents the 12-month outcomes of toric implantable collamer lens (ICL) implantation in eyes with hyperopic astigmatism.

View Article and Find Full Text PDF

Purpose: To determine clinical and refractive results after the implantation of EyeCryl Phakic Toric intraocular lens in patients with stable keratoconus.

Methods: The study included all patients diagnosed with keratoconus who underwent implantation of an EyeCryl Phakic Toric intraocular lens (Biotech Healthcare Holding; Ahmedabad, India) in at least one eye and had a follow-up of at least 12 months. Visual and refractive data were collected for all patients, along with corneal tomography measurements using Pentacam, and vault measurement using optical coherence tomography.

View Article and Find Full Text PDF

Digital vs manual axis marking for toric phakic intraocular lens alignment: prospective randomized intraindividual trial.

J Cataract Refract Surg

January 2025

From the Department of Ophthalmology, Medical University of Graz, Graz, Austria (List, Dirisamer, Glatz, Gran, Wedrich, Steinwender); Department of Ophthalmology, University Hospital, LMU Munich, Munich, Germany (Dirisamer, Mayer); Department of Ophthalmology, Goethe University, Frankfurt am Main, Germany (Shajari).

Purpose: To compare visual and refractive outcomes and postoperative axis alignment for toric implantable collamer lens (ICL) implantation in astigmatic myopia using manual vs digital marking techniques.

Setting: Department of Ophthalmology, Medical University of Graz, Graz, Austria.

Design: Prospective randomized single-centered intraindividual comparison.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!