Objective: The aim of this study was to use antimicrobial efficacy endpoint methodology to determine compatibility of multipurpose disinfecting solutions (MPSs), lens cases, and hydrogel lenses for disinfection (AEEMC) against International Organization for Standardization (ISO)-specified microorganisms and clinical ocular isolates of Stenotrophomonas maltophilia.
Methods: Six MPSs (PQ/Aldox 1, 2, and 3; PQ/Alexidine; PQ/PHMB; and PHMB) were challenged against ISO-specified microorganisms and S. maltophilia using the AEEMC test. AEEMC tests were performed with and without balafilcon A, etafilcon A, and senofilcon A lenses in lens cases with organic soil. Exposure times included disinfection time (DT) and 24 hr. Additionally, all six MPSs were challenged with two strains of S. maltophilia, based on the ISO Stand-alone test.
Results: The efficacy against bacteria for PQ/Aldox and PQ/Alexidine MPSs was not diminished by the presence of lenses. The efficacy of PQ/PHMB and PHMB MPSs against Serratia marcescens was significantly reduced compared with the no-lens control at DT for at least one lens type. The PHMB MPS with lenses present also demonstrated reduced efficacy against Staphylococcus aureus at DT versus the control. PQ/Aldox MPSs retained activity against Fusarium solani with lenses present; however, all other test MPSs demonstrated reduced F. solani efficacy at DT with lenses present. With lenses, all MPSs showed reduced efficacy against Candida albicans.
Conclusions: AEEMC antimicrobial efficacy test results vary based on challenge microorganism, contact lenses, and MPS biocide systems. This study highlights the importance of evaluating MPSs for compatibility with lenses and lens cases.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5839710 | PMC |
http://dx.doi.org/10.1097/ICL.0000000000000308 | DOI Listing |
Radiat Environ Biophys
January 2025
Radiation Physics, Faculty of Science, Al -Azhar University, Cairo, Egypt.
This study aimed to evaluate the dosimetric and clinical outcomes of flattening filter (FF) versus flattening filter-free (FFF) beams in head and neck cancer (HNC) patients treated with volumetric modulated arc therapy (VMAT). Twenty-four patients with 70/59.4/54 Gy dose prescribed in 33 fractions with simultaneous integrated boost treatment were retrospectively analyzed to compare treatment delivery efficiency, target coverage, sparing of organs at risk (OARs), and remaining volume at risk (RVR) in two HNC groups (nasopharyngeal and oropharyngeal).
View Article and Find Full Text PDFMed J Malaysia
January 2025
Universiti Sains Malaysia, School of Medical Sciences, Department of Ophthalmology and Visual Science, Health Campus, Kubang Kerian, Kelantan, Malaysia.
Introduction: Cataract is a leading cause of visual impairment globally and in Malaysia, with surgery being the definitive treatment. While intracapsular cataract extraction (ICCE) is now less commonly performed due to advancements in surgical techniques, it remains essential in specific cases, such as those with weak zonular support. This study aims to evaluate the incidence, clinical profiles, and visual outcomes of patients who underwent ICCE, with or without intraocular lens (IOL) implantation, at Hospital Melaka, Malaysia, over the past decade.
View Article and Find Full Text PDFTunis Med
January 2025
Department of Ophtalmology, Habib Bourguiba University Hospital, University of Sfax, Sfax, Tunisia.
Aim: To report the clinical and therapeutic particularities of pediatric keratoconus (KC).
Methods: Retrospective study focusing on patients aged less than 18 years, presenting with KC and followed in a tertiary reference center in Sfax, Tunisia.
Results: Our study involved 38 eyes of 20 children.
GMS Ophthalmol Cases
December 2024
Department of Ophthalmology, Disha Eye Hospital, Siliguri, India.
Background: Pseudophakic cystoid macular edema (CME) following primary anterior-chamber intraocular lens (ACIOL) implantations is commonly seen. Intravitreal triamcinolone acetonide (IVTA) injections have shown significant improvement in visual acuity and retinal thickness in refractory pseudophakic CME. Pseudohypopyon following IVTA injection is a known entity.
View Article and Find Full Text PDFBMJ Open
December 2024
Department of Ophthalmology & Clinical Centre of Optometry, Peking University People's Hospital, Beijing, China.
Objectives: To examine the ocular biometric parameters and predict the annual growth rate of the physiological axial length (AL) in Chinese preschool children aged 4-6 years old.
Methods: This retrospective cross-sectional study included 1090 kindergarten students (1090 right eyes) between the ages of 4 and 6 years from Pinggu and Chaoyang District, Beijing. Dioptre values were ascertained following cycloplegic autorefraction.