AI Article Synopsis

  • The study aimed to evaluate the effectiveness of F-FDG PET/CT imaging in diagnosing infective endocarditis (IE) in patients with prosthetic valves and cardiac implantable electronic devices.
  • Researchers analyzed data from 41 patients using various interpretation criteria, discovering that visual evaluation combining different types of PET images improved diagnostic accuracy significantly.
  • The study found that higher FDG uptake in certain areas was strongly associated with confirmed IE, highlighting a specific SUVmax threshold as a potential diagnostic tool.

Article Abstract

Purpose: The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of F-FDG PET/CT in these patients and analyse the interpretation criteria.

Methods: We included 41 patients suspected of having IE by the Duke criteria who underwent F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up.

Results: We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∆SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71).

Conclusion: The value of F-FDG PET/CT in the diagnosis of suspected IE of PVs and CIEDs is highly dependent on patient preparation and the method used for image interpretation. Based on our results, the best method is to consider a study positive for IE when FDG uptake is present in both AC PET and NAC PET images.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-016-3463-9DOI Listing

Publication Analysis

Top Keywords

pet images
44
analysis pet
24
f-fdg pet/ct
16
visual analysis
16
nac pet
16
pet
12
images
11
diagnostic accuracy
8
infective endocarditis
8
cardiac implantable
8

Similar Publications

Background: Cocaine Use Disorder (CUD) remains a significant problem in the United States, with high rates of relapse and no present FDA-approved treatment. The acetylcholine neurotransmitter system, specifically through modulation of muscarinic acetylcholine receptor (mAChR) function, has shown promise as a therapeutic target for multiple aspects of CUD. Enhancement of the M mAChR subtype via positive allosteric modulation has been shown to inhibit the behavioral and neurochemical effects of cocaine across several rodent models of CUD.

View Article and Find Full Text PDF

Purpose Of Review: Our purpose was to discuss the advantages and disadvantages of various noninvasive imaging modalities in the evaluation of cardiovascular disease (CVD) in patients with autoimmune rheumatic diseases (ARDs). The detailed knowledge of imaging modalities will facilitate the diagnosis and follow up of CVD in ARDs.

Recent Findings: Autoimmune Rheumatic Diseases (ARDs) are characterized by alterations in immunoregulatory system of the body.

View Article and Find Full Text PDF

Purpose: Recent advancements in imaging, particularly 18F-fluorodeoxyglucose positron-emission tomography-computed tomography (FDG-PET/CT), have improved the detection of involved lymph nodes, thus influencing staging accuracy and potentially treatment outcomes. This study is a post hoc analysis of the GAZAI trial data to evaluate the impact of FDG-PET/CT versus computed tomography (CT) alone on radiation target volumes for involved-site radiotherapy (IS-RT) in early-stage follicular lymphoma (FL).

Methods: All patients in the GAZAI trial underwent pretherapeutic FDG-PET/CT examinations, which were subject to central quality control.

View Article and Find Full Text PDF

CT Predictors of Angiolymphatic Invasion in Non-Small Cell Lung Cancer 30 mm or Smaller.

Radiology

January 2025

From the Department of Radiology, Harbin Medical University Cancer Hospital, Harbin, China (Q.S., P.L., J.Z.); and Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai, 1 Gustave L. Levy Pl, New York, NY 10029 (Q.S., P.L., R.Y., D.F.Y., C.I.H.).

Background Angiolymphatic invasion (ALI) is an important prognostic indicator in non-small cell lung cancer (NSCLC). However, few studies focus on radiologic features for predicting ALI in patients with early-stage NSCLCs 30 mm or smaller. Purpose To identify radiologic features for predicting ALI in NSCLCs 30 mm or smaller in maximum diameter.

View Article and Find Full Text PDF

PET Imaging of Solid Tumors with a G-Quadruplex-Targeting F-Labeled Peptide Probe.

J Med Chem

January 2025

Guangdong Medicine-Engineering Interdisciplinary Technology Research Center, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China.

Positron emission tomography (PET) is a common imaging technique and can provide accurate information about the size, shape, and location of tumors. Recent evidence has shown that G-quadruplex structures (G4s) are identified in human oncogenes, and these special structures are recognized as diagnostic cancer markers and drug targets for anticancer therapies. Although a number of techniques for in vivo imaging of G4s have been developed, achieving sufficient sensitivity and selectivity in vivo remains challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!