A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Influence of Injected Volume on Discomfort During Administration of Digital Block. | LitMetric

Background: Digital nerve block is associated with pain. In a search for methods to reduce the discomfort, we investigated how the volume of anaesthetic fluid influences pain during subcutaneous digital nerve block, and how it affects the success of the anaesthesia.

Methods: A randomized blinded prospective study was performed on 36 healthy volunteers. The single injection subcutaneous digital block technique was used to anaesthetize the participants´ 4th digit on both hands. The same amount of lidocaine was used, but in two different volumes; 1 ml 2% lidocaine and 2ml 1% lidocaine. After each injection the participant was asked to estimate pain intensity on a visual analogue scale (VAS). The distribution of anaesthesia was then measured by using a Semmes-Weinstein 4.56 monofilament. Finally, participants gave a verbal assessment of which injection was least painful.

Results: In total, 72 blocks were performed. There were no statistically significant differences in pain intensity or preference between the two groups. Furthermore, the 1 ml injection gave poorer anaesthesia and had longer time to onset. Neither injection anaesthetized the dorsal aspect of the proximal phalanx.

Conclusions: The two volumes cause the same degree of discomfort. Greater volume gives a greater area of distribution and more rapid onset of anaesthesia. It seems unreasonable to use a smaller volume of more concentrated anaesthetic when performing the subcutaneous technique.

Download full-text PDF

Source
http://dx.doi.org/10.1142/S2424835516500363DOI Listing

Publication Analysis

Top Keywords

digital block
8
digital nerve
8
nerve block
8
subcutaneous digital
8
pain intensity
8
injection
5
influence injected
4
volume
4
injected volume
4
volume discomfort
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!