A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dose reduction in paediatric cranial CT via iterative reconstruction: a clinical study in 78 patients. | LitMetric

Aim: To assess how adaptive statistical iterative reconstruction (ASIR) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT) in children.

Materials And Methods: Non-contrast cranial CT acquired in 78 paediatric patients (age 0-12 years) were evaluated. The images were acquired and processed using four different protocols: Group A (control): 120 kV, filtered back projection (FBP), n=18; Group B: 100 kV, FBP, n=22; Group C: 100 kV, scan and reconstruction performed with 20% ASIR, n=20; Group D1: 100 kV, scan and reconstruction performed with 30% ASIR, n=18; Group D2: raw data from Group D1 reconstructed using a blending of 40% ASIR and 60% FBP, n=18. The effective dose was calculated and the image quality was assessed quantitatively and qualitatively.

Results: Compared to Group A, Groups C and D1/D2 showed a significant reduction of the dose-length product (DLP) by 34.4% and 64.4%, respectively. All experimental groups also showed significantly reduced qualitative levels of noise, contrast, and overall diagnosability. Diagnosis-related confidence grading showed Group C to be adequate for everyday clinical practice. Quantitative measures of Groups B and C were comparable to Group A with only few parameters compromised. Quantitative scores in Groups D1 and D2 were mainly lower compared to Group A, with Group D2 performing better than Group D1. Group D2 was considered adequate for follow-up imaging of severe acute events such as bleeding or hydrocephalus.

Discussion: The use of ASIR combined with low tube voltage may reduce radiation significantly while maintaining adequate image quality in non-contrast paediatric cCT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.crad.2016.06.115DOI Listing

Publication Analysis

Top Keywords

group
13
image quality
12
group 100 kv
12
dose reduction
8
iterative reconstruction
8
quality non-contrast
8
non-contrast cranial
8
fbp n=18
8
n=18 group
8
100 kv scan
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!