Outcome After Myocardial Infarction Treated With Resolute Integrity and Promus Element Stents: Insights From the DUTCH PEERS (TWENTE II) Randomized Trial.

Rev Esp Cardiol (Engl Ed)

Cardiology Department, Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, The Netherlands; Department Health Technology and Services Research, MIRA - Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands. Electronic address:

Published: December 2016

Introduction And Objectives: In acute myocardial infarction (MI), novel highly deliverable drug-eluting stents (DES) may be particularly valuable as their flexible stent designs might reduce device-induced traumas to culprit lesions. The aim of the study was to assess the safety and efficacy of percutaneous coronary interventions with 2 novel durable polymer-coated DES in patients with acute MI.

Methods: The prospective, randomized DUTCH PEERS (TWENTE II) multicenter trial compares Resolute Integrity and Promus Element stents in 1811 all-comer patients, of whom 817 (45.1%) were treated for ST-segment elevation MI or non-ST-segment elevation MI and the 2-year outcome is available in 99.9%. The primary clinical endpoint is target vessel failure (TVF), a composite of cardiac death, target vessel related MI, or target vessel revascularization.

Results: Of all 817 patients treated for acute MI, 421 (51.5%) were treated with Resolute Integrity and 396 (48.5%) with Promus Element stents. At the 2-year follow-up, the rates of TVF (7.4% vs 6.1%; P = .45), target lesion revascularization (3.1% vs 2.8%; P = .79), and definite stent thrombosis (1.0% vs 0.5%; P = .69) were low for both stent groups. Consistent with these findings in all patients with acute MI, outcomes for the 2 DES were favorable and similar in both, with 370 patients with ST-segment elevation MI (TVF, 5.1% vs 4.9%; P = .81) and 447 patients with non-ST-segment elevation MI (TVF, 9.0% vs 7.5%; P = .56).

Conclusions: Resolute Integrity and Promus Element stents were both safe and efficacious in treating patients with acute MI. The present 2-year follow-up data underline the safety of using these devices in this particular clinical setting.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rec.2016.05.029DOI Listing

Publication Analysis

Top Keywords

resolute integrity
16
promus element
16
element stents
16
integrity promus
12
patients acute
12
target vessel
12
myocardial infarction
8
treated resolute
8
dutch peers
8
peers twente
8

Similar Publications

Cost-Effectiveness of Three Different New-Generation Drug-Eluting Stents in the Randomised BIO-RESORT Trial at 3 Years.

Pharmacoecon Open

January 2025

Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, 7512 KZ, Enschede, The Netherlands.

Background And Objective: Evidence on health economic outcomes for percutaneous coronary intervention (PCI) comparing different contemporary drug-eluting stents (DES) with each other is scarce, as most previous randomised DES trials did not assess such aspects. This prespecified health economic evaluation of the Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population (BIO-RESORT) trial aimed to compare at 3-year follow-up both health effects and costs of PCI with one of three new-generation drug-eluting stents (DES) in patients with obstructive coronary artery disease.

Methods: The randomised BIO-RESORT trial assessed in 3514 patients the ultrathin-strut biodegradable polymer Orsiro sirolimus-eluting stent (SES) and very-thin-strut Synergy everolimus-eluting (EES) stent versus the thin-strut durable polymer Resolute Integrity zotarolimus-eluting stent (ZES).

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of different coronary stents in patients at high bleeding risk (HBR) who require short-term antiplatelet therapy, finding that drug-eluting stents (DESs) are generally better than bare metal stents (BMSs).
  • A network meta-analysis covering four trials with over 6,600 HBR patients showed that DESs reduced major adverse cardiovascular events (MACEs) and improved safety outcomes compared to BMSs, particularly with 1-month dual antiplatelet therapy.
  • Among the DESs analyzed, the Orsiro stent ranked the highest for effectiveness, closely followed by Synergy, showing reduced rates of revascularization and stent thrombosis, which contributed
View Article and Find Full Text PDF

In our groundbreaking exploration, we meticulously delve into the relationship between environmental policy stringency, international trade dynamics, and financial openness within the BRICS group (Brazil, Russia, India, China, and South Africa) spanning from 1996 to 2021. With a focus on critical variables such as economic growth and technological innovation, our empirical findings challenge conventional wisdom. Surprisingly, we found that those stringent environmental policies, when standing alone, do not invariably lead to reduce CO emissions.

View Article and Find Full Text PDF

Purpose: Intimate partner violence (IPV) is a significant public health concern exacerbated by the pandemic. Experiences of violence vary based on geographic location and living in rural communities has been found, in some contexts, to amplify consequences of IPV. Resilience, the ability to survive and thrive despite facing adversity, has long been a dominant narrative within IPV literature, yet little is known about how resilience is cultivated among rural women experiencing violence.

View Article and Find Full Text PDF

Final 5-Year Report of the Randomized BIO-RESORT Trial Comparing 3 Contemporary Drug-Eluting Stents in All-Comers.

J Am Heart Assoc

November 2022

Department of Cardiology Thoraxcentrum Twente, Medisch Spectrum Twente Enschede The Netherlands.

Background In a previous trial, higher 5-year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus-eluting stents (SES). We assessed 5-year safety and efficacy of all-comers as well as patients with diabetes treated with SES or Synergy everolimus-eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). Methods and Results The randomized BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) trial enrolled 3514 all-comer patients at 4 Dutch cardiac centers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!