Rapid identification and quantitation for oral bacteria based on short-end capillary electrophoresis.

Talanta

Institute of Photonics and Bio-medicine, Graduate School of Science, East China University of Science and Technology, 130 Meilong Road, Shanghai, 200237 China; Department of Applied Physics, Graduate School of Engineering, Osaka University, Yamadaoka, Suita-city, Osaka, 565-0871 Japan; School of Optoelectronic Engineering, ChangZhou Institute of Technology, 299 South Tongjiang Road, Changzhou, Jiangsu, 213002 China. Electronic address:

Published: November 2016

High-speed capillary electrophoresis (HSCE) is a promising technology applied in ultra-rapid and high-performance analysis of biomolecules (such as nucleic acids, protein). In present study, the short-end capillary electrophoresis coupled with one novel space domain internal standard method (SDIS) was employed for the rapid and simultaneous analysis of specific genes from three oral bacteria (Porphyromonas gingivalis (P.g), Treponema denticola (T.d) and Tannerela forsythia (T.f)). The reliability, reproducibility and accuracy properties of above mentioned SDIS method were investigated in detail. The results showed the target gene fragments of P.g, T.d and T.f could be precisely, fast identified and quantitated within 95s via present short-end CE system. The analyte concentration and the ratio of space domain signals (between target sample and internal standard sample) featured a well linear relationship calculated via SDIS method. And the correlation coefficients R(2) and detection limits for P.g, T.d, T.f genes were 0.9855, 0.9896, 0.9969 and 0.077, 0.114 and 0.098ng/μl, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2016.07.049DOI Listing

Publication Analysis

Top Keywords

capillary electrophoresis
12
oral bacteria
8
short-end capillary
8
space domain
8
internal standard
8
sdis method
8
rapid identification
4
identification quantitation
4
quantitation oral
4
bacteria based
4

Similar Publications

Capillary Electrophoresis-Mass Spectrometry for Top-Down Proteomics.

Annu Rev Anal Chem (Palo Alto Calif)

January 2025

Department of Chemistry, Michigan State University, East Lansing, Michigan, USA; email:

Mass spectrometry (MS)-based top-down proteomics (TDP) characterizes proteoforms in cells, tissues, and biological fluids (e.g., human plasma) to better our understanding of protein function and to discover new protein biomarkers for disease diagnosis and therapeutic development.

View Article and Find Full Text PDF

Serum HDL and their subfractions are impaired in multisystem inflammatory syndrome in children (MIS-C).

J Transl Med

January 2025

Dipartimento di Pediatria Generale e d'Urgenza, AORN Santobono-Pausilipon, Naples, Italy.

Background: Multisystem inflammatory syndrome in children (MIS-C) is a severe post-COVID condition due to a delayed hyperimmune response to SARS-CoV-2. High-density lipoproteins (HDL) are pivotal players in inflammatory and immune modulation through the remodeling of their subfractions.

Methods: This study aimed to evaluate serum levels of cholesterol, HDL, and HDL subfractions (HDL-SUB) to define their role in the pathogenesis of MIS-C and their potential use as biomarkers of this condition.

View Article and Find Full Text PDF

The development and validation of an accurate, selective, and eco-friendly capillary zone electrophoretic detection (CZE) method has been presented for concurrent measurement of inorganic and organic anions including chloride, sulfate, formic acid, citric acid, acetic acid, phosphate, and glutamic acid in Human Milk Oligosaccharides (HMOs) for the first time. An electrolyte composed of an aqueous solution of benzoic acid, 16.38 mM; l-histidine, 24.

View Article and Find Full Text PDF

Genotype-phenotype correlation and potential genetic risk in the compound heterozygosity for unstable hemoglobins (UHbs) and α-thalassemia were discussed. Capillary electrophoresis and gene sequencing helped to establish the diagnosis. Hematological analysis showed the following findings: MCV 80.

View Article and Find Full Text PDF

Advancements in food technology have increased the need for thorough analysis to ensure food safety, quality, and compliance with regulatory requirements. Capillary electrophoresis-mass spectrometry (CE-MS) has emerged as a powerful tool in food analysis due to its high separation efficiency, low sample consumption, and ability to handle complex matrices. However, challenges such as the use of volatile running buffers and maintaining the stability of the electrical circuit connecting the CE and MS systems have been addressed through advancements in interface designs, such as sheathless systems and optimized sheath-liquid compositions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!