Following series of synthetic cannabinoid and synthetic cathinone derivatives, the illicit drug market has begun to see increased incidence of synthetic opioids including fentanyl and its derivatives, and other chemically unrelated opioid agonists including AH-7921 and MT-45. Among the most frequently encountered compounds in postmortem casework have been furanyl fentanyl (N-(1-(2-phenylethyl)-4-piperidinyl)-N-phenylfuran-2-carboxamide, Fu-F) and U-47700 (trans-3,4-dichloro-N-(2-(dimethylamino)cyclohexyl)-N-methylbenzamide). Both drugs have been reported to be present in the heroin supply and to be gaining popularity among recreational opioid users, but were initially developed by pharmaceutical companies in the 1970s as candidates for development as potential analgesic therapeutic agents. A method was developed and validated for the analysis of U-47700, U-50488 and furanyl fentanyl in blood specimens. A total of 20 postmortem cases, initially believed to be heroin or other opioid-related drug overdoses, were submitted for quantitative analysis. The analytical range for U-47770 and U-50488 was 1-500 and 1-100 ng/mL for furanyl fentanyl. The limit of detection was 0.5 ng/mL for all compounds. Within the scope of the method, U-47700 was the only confirmed drug in 11 of the cases, 5 cases were confirmed for both U-47700 and furanyl fentanyl, and 3 cases were confirmed only for furanyl fentanyl. The mean and median blood concentrations for U-47700 were 253 ng/mL (±150) and 247 ng/mL, respectively, range 17-490 ng/mL. The mean and median blood concentrations for furanyl fentanyl were 26 ng/mL (±28) and 12.9 ng/mL, respectively, range 2.5-76 ng/mL. Given the widespread geographical distribution and increase in prevalence in postmortem casework, toxicology testing should be expanded to include testing for "designer opioids" in cases with histories consistent with opioid overdose but with no traditional opioids present or insufficient quantities to account for death.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jat/bkw086DOI Listing

Publication Analysis

Top Keywords

furanyl fentanyl
28
postmortem casework
12
synthetic opioids
8
u-47700 u-50488
8
u-50488 furanyl
8
fentanyl
8
ng/ml
8
cases confirmed
8
median blood
8
blood concentrations
8

Similar Publications

Ultrasensitive electrochemiluminescencent multivalent aptamer sensor based on energy and electron transfer dual quenching tactics.

Mikrochim Acta

November 2024

Jiangsu Key Laboratory of Advanced Catalytic Materials and Technology, School of Petrochemical Engineering, Changzhou University, Changzhou, 213164, China.

An efficient "on-off-on" electrochemiluminescence (ECL) aptasensor utilizing dual-mechanism quenching was constructed for detecting furanyl fentanyl (FuF). The first signal "on" state was achieved by novel dual-ligand zinc metal-organic frameworks (Zn-MOFs), which were synthesized by self-assembly reaction using zinc atom clusters as metal nodes, achieving strong and stable ECL emission. The "off" state was realized by the energy and electron quenching effect of copper-doped WO.

View Article and Find Full Text PDF

Resonance energy transfer (RET) quenching is significantly important for developing electrochemiluminescence (ECL) sensors, but RET platforms face challenges like interference from other fluorescent substances and reliance on energy transfer efficiency. This study used Zn-PTC, formed by zinc ions coordinated with perylene-3,4,9,10-tetracarboxylate, as a dual-mechanism quencher to reduce the ECL intensity of carbon nitride nanosheets (Tg-CNNSs). CoO/NiCoO acts as a coreaction promoter, enhancing and stabilizing the luminescence of Tg-CNNSs.

View Article and Find Full Text PDF

Fentanyl is a potent synthetic opioid with an alarmingly low lethal dosage of 2 mg. The equipment necessary to detect fentanyl in field settings (e.g.

View Article and Find Full Text PDF

Fentanyl and fentanyl analogs are the main cause of recent overdose deaths in the United States. The presence of fentanyl analogs in illicit drugs makes it difficult to estimate their potencies. This makes the detection and differentiation of fentanyl analogs critically significant.

View Article and Find Full Text PDF

The abuse of illicit drugs poses serious threats to the physical and mental health of users, as well as to the overall safety and welfare of society. In this work, we present a newly developed technique for drug detection based on mass spectrometry. This technique combines Leidenfrost desorption with low-temperature arc plasma ionization mass spectrometry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!