Benchtop in vitro experiments are valuable tools for investigating the cardiovascular system and testing medical devices. Accurate reproduction of the physiologic flow waveforms at various anatomic locations is an important component of these experimental methods. This study discusses the design, construction, and testing of a low-cost and fully programmable pulsatile flow pump capable of continuously producing unlimited cycles of physiologic waveforms. It consists of a gear pump actuated by an AC servomotor and a feedback algorithm to achieve highly accurate reproduction of flow waveforms for flow rates up to 300 ml/s across a range of loading conditions. The iterative feedback algorithm uses the flow error values in one iteration to modify the motor control waveform for the next iteration to better match the desired flow. Within four to seven iterations of feedback, the pump replicated desired physiologic flow waveforms to within 2% normalized RMS error (for flow rates above 20 mL/s) under varying downstream impedances. This pump device is significantly more affordable (∼10% of the cost) than current commercial options. More importantly, the pump can be controlled via common scientific software and thus easily implemented into large automation frameworks.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1115/1.4034561 | DOI Listing |
Neurophotonics
January 2025
California Institute of Technology, Department of Electrical Engineering, Pasadena, California, United States.
Significance: Cerebral blood flow (CBF) and cerebral blood volume (CBV) are key metrics for regional cerebrovascular monitoring. Simultaneous, non-invasive measurement of CBF and CBV at different brain locations would advance cerebrovascular monitoring and pave the way for brain injury detection as current brain injury diagnostic methods are often constrained by high costs, limited sensitivity, and reliance on subjective symptom reporting.
Aim: We aim to develop a multi-channel non-invasive optical system for measuring CBF and CBV at different regions of the brain simultaneously with a cost-effective, reliable, and scalable system capable of detecting potential differences in CBF and CBV across different regions of the brain.
Diabet Med
January 2025
School of Medicine, University of Galway, Galway, Ireland.
Aims: To describe the sonographic features of active Charcot neuro-osteoarthropathy (CNO) and assess the potential role of ultrasound in identifying those with active CNO.
Methods: Using a prospective case-series study design we assessed the sonographic features of 14 patients with a diagnosis of diabetes presenting with clinical signs and symptoms suspicious for active CNO. Patients had standard weight-bearing plain X-Ray and, where possible, MRI to evaluate the presence of active CNO.
Sci Rep
January 2025
Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai, India.
The local pulse wave velocity (PWV) from large elastic arteries and its pressure-dependent changes within a cardiac cycle are potential biomarkers for cardiovascular risk stratification. However, pulse wave reflections can impair the accuracy of local PWV measurements. We propose a method to measure pressure-dependent variations in local PWV while minimizing the influence of pulse wave reflections.
View Article and Find Full Text PDFAnn Card Anaesth
January 2025
Division of Cardiothoracic and Vascular Anesthesia, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, India.
Sci Rep
January 2025
School of Engineering, The University of Manchester, Manchester, UK.
This study examines how heart rate (HR) affects hemodynamics in a South African infant with Coarctation of the Aorta. Computed tomography angiography segments aortic coarctation anatomy; Doppler echocardiography derives inlet flow waveforms. Simulations occur at 100, 120, and 160 beats per minute, representing reduced, resting, and elevated HR levels.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!