Biomechanical analysis of a novel hemipelvic endoprosthesis during ascending and descending stairs.

Proc Inst Mech Eng H

School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, P.R. China School of Mechanical Engineering, University of Leeds, Leeds, UK.

Published: October 2016

In this study, the biomechanical characteristic of a newly developed adjustable hemipelvic prosthesis under dynamic loading conditions was investigated using explicit finite element method. Both intact and reconstructed pelvis models, including pelvis, femur and soft tissues, were established referring to human anatomic data using a solid geometry of a human pelvic bone. Hip contact forces during ascending stairs and descending stairs were imposed on pelvic models. Results showed that maximum von Mises stresses in reconstructed pelvis were 421.85 MPa for prostheses and 109.12 MPa for cortical bone, which were still within a low and elastic range below the yielding strength of Ti-6Al-4V and cortical bone, respectively. Besides, no significant difference of load transferring paths along pelvic rings was observed between the reconstructed pelvis and natural pelvis models. And good agreement was found between the overall distribution of maximum principal stresses in trabecular bones of reconstructed pelvis and natural pelvis, while at limited stances, principal stresses in trabecular bone of reconstructed pelvis were slightly lower than natural pelvis. The results indicated that the load transferring function of pelvis could be restored by this adjustable hemipelvic prosthesis. Moreover, the prosthesis was predicted to have a reliable short- and long-term performance. However, due to the occurrence of slightly lower principal stresses at a few stances, a porous structure applied on the interface between the prosthesis and bone would be studied in future work to obtain better long-term stability.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0954411916663970DOI Listing

Publication Analysis

Top Keywords

reconstructed pelvis
20
natural pelvis
12
principal stresses
12
pelvis
10
descending stairs
8
adjustable hemipelvic
8
hemipelvic prosthesis
8
pelvis models
8
cortical bone
8
load transferring
8

Similar Publications

Dimensions of the pelvic and skull bones are known to be sexually dimorphic in various population groups. The recovery of these bones is potentially beneficial in estimating the sex in forensic cases. Since both bones are not always available for forensic analysis, standards for sex estimation must be established for other bones of the postcranial skeleton.

View Article and Find Full Text PDF

Background: The occurrence of periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA) might be associated with the proximal femoral morphology and the pelvis. PFFs in short stem THA are associated with an increased Canal Flare Index. PFFs in straight stem THA show a decreased Canal Flare Index.

View Article and Find Full Text PDF

Report of a Rare Case of Acute Abdominal Pain Post-partum: Spontaneous Ureteral Rupture.

Cureus

December 2024

Radiology, West Suffolk NHS Foundation Trust, Bury St Edmunds, GBR.

Spontaneous ureteral rupture is a rare cause of acute abdominal pain, particularly unusual during pregnancy or the post-partum period. While pregnancy-related changes like ureteral compression and dilation may play a role, no definitive mechanisms have been established. Clinicians should suspect ureteric injury in post-partum patients with free pelvic fluid.

View Article and Find Full Text PDF

Background: Prospective trial evidence is lacking regarding the application of enhanced recovery after surgery (ERAS) in transvaginal pelvic floor reconstruction surgery among older patients. Our study aimed to investigate whether implementing the ERAS protocol could enhance post-operative recovery in this patient population.

Methods: Older patients undergoing elective transvaginal pelvic floor reconstruction surgery were randomly assigned to either the ERAS group or the conventional group.

View Article and Find Full Text PDF

Determinants for successful medullary fixation of the superior ramus.

Injury

January 2025

Department of Orthopaedic Surgery, Cedars - Sinai Medical Center, Los Angeles, CA, USA. Electronic address:

Objectives: The purpose of this study is to determine what demographic and anatomical variables affect successful placement of a superior medullary ramus screw, and how they affect the maximal diameter of that screw.

Methods: Design: Prognostic Level IV SETTING: Level I Trauma Center Patients/Participants: Two hundred consecutive patients underwent computed tomography (CT) of the pelvis. We included those patients aged 18 and older without osseous injury or abnormalities precluding measurement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!