Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m(2) per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m(2) per MW injected beam power is measured.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4960349DOI Listing

Publication Analysis

Top Keywords

absolute calibration
16
stray radiation
16
wendelstein 7-x
12
sniffer probes
8
power levels
8
vacuum vessel
8
calibration coefficients
8
kw/m2 injected
8
injected beam
8
beam power
8

Similar Publications

Introduction Incorporation of mammographic density to breast cancer risk models could improve risk stratification to tailor screening and prevention strategies according to risk. Robust evaluation of the value of adding mammographic density to models with comprehensive information on questionnaire-based risk factors and polygenic risk score is needed to determine its effectiveness in improving risk stratification of such models. Methods We used the Individualized Coherent Absolute Risk Estimator (iCARE) tool for risk model building and validation to incorporate density to a previously validated literature-based model with questionnaire-based risk factors and a 313-variant polygenic risk score (PRS).

View Article and Find Full Text PDF

The increasing interest in DNA methylation (DNAm) analysis within the forensic scientific community prompted a collaborative project by Ge.F.I.

View Article and Find Full Text PDF

Objective Endometrial lesions are a frequent complication following breast cancer, and current diagnostic tools have limitations. This study aims to develop a machine learning-based nomogram model for predicting the early detection of endometrial lesions in patients. The model is designed to assess risk and facilitate individualized treatment strategies for premenopausal breast cancer patients.

View Article and Find Full Text PDF

Validation of Sleep Measurements of an Actigraphy Watch: Instrument Validation Study.

JMIR Form Res

January 2025

Department of Biomedical Informatics, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.

Background: The iAide2 (Tokai) physical activity monitoring system includes diverse measurements and wireless features useful to researchers. The iAide2's sleep measurement capabilities have not been compared to validated sleep measurement standards in any published work.

Objective: We aimed to assess the iAide2's sleep duration and total sleep time (TST) measurement performance and perform calibration if needed.

View Article and Find Full Text PDF

A method to determine electron temperature within a plasma by the spectral analysis of atomic tungsten emission has been explored. The technique was applied to a post-discharge region immediately following a high voltage nanosecond pulsed discharge in air with tungsten electrodes. Atomic tungsten lines are readily observed in the weak emission spectrum within the post-discharge region for many microseconds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!