Analysis of the microcirculation is currently performed offline, is time consuming and operator dependent. The aim of this study was to assess the ability and efficiency of the automatic analysis software CytoCamTools 1.7.12 (CC) to measure microvascular parameters in comparison with Automated Vascular Analysis (AVA) software 3.2. 22 patients admitted to the cardiothoracic intensive care unit following cardiac surgery were prospectively enrolled. Sublingual microcirculatory videos were analysed using AVA and CC software. The total vessel density (TVD) for small vessels, perfused vessel density (PVD) and proportion of perfused vessels (PPV) were calculated. Blood flow was assessed using the microvascular flow index (MFI) for AVA software and the averaged perfused speed indicator (APSI) for the CC software. The duration of the analysis was also recorded. Eighty-four videos from 22 patients were analysed. The bias between TVD-CC and TVD-AVA was 2.20 mm/mm (95 % CI 1.37-3.03) with limits of agreement (LOA) of -4.39 (95 % CI -5.66 to -3.16) and 8.79 (95 % CI 7.50-10.01) mm/mm. The percentage error (PE) for TVD was ±32.2 %. TVD was positively correlated between CC and AVA (r = 0.74, p < 0.001). The bias between PVD-CC and PVD-AVA was 6.54 mm/mm (95 % CI 5.60-7.48) with LOA of -4.25 (95 % CI -8.48 to -0.02) and 17.34 (95 % CI 13.11-21.57) mm/mm. The PE for PVD was ±61.2 %. PVD was positively correlated between CC and AVA (r = 0.66, p < 0.001). The median PPV-AVA was significantly higher than the median PPV-CC [97.39 % (95.25, 100 %) vs. 81.65 % (61.97, 88.99), p < 0.0001]. MFI categories cannot estimate or predict APSI values (p = 0.45). The time required for the analysis was shorter with CC than with AVA system [2'42″ (2'12″, 3'31″) vs. 16'12″ (13'38″, 17'57″), p < 0.001]. TVD is comparable between the two softwares, although faster with CC software. The values for PVD and PPV are not interchangeable given the different approach to assess microcirculatory flow.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-016-9928-3DOI Listing

Publication Analysis

Top Keywords

ava software
12
ability efficiency
8
efficiency automatic
8
automatic analysis
8
analysis software
8
measure microvascular
8
microvascular parameters
8
vessel density
8
software
6
analysis
5

Similar Publications

This systematic review and meta-analysis evaluates the potential of four-dimensional flow magnetic resonance imaging (4DFM) in assessing aortic stenosis (AS) compared to traditional imaging modalities like two-dimensional phase contrast MRI (2D MRI) and transthoracic echocardiography (TTE). AS is a common and severe valvular heart disease, particularly in older adults, requiring accurate diagnosis for proper clinical management. Conventional imaging methods have limitations in capturing complex flow dynamics, prompting the need for advanced modalities like 4DFM.

View Article and Find Full Text PDF

This paper proposes a smartphone-based method for measuring Blood Pressure (BP) using the oscillometric method. For oscillometry, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force.

View Article and Find Full Text PDF

Background: Selecting intervention strategies for renal artery aneurysms (RAAs) is challenging especially for those located at the vessel bifurcation. The relationship between the aneurysm and renal branches could not always be accurately viewed from traditional computed tomography angiography (CTA) images.

Case Presentation: This study proposed a new method to investigate the anatomy and affected vessel branches of RAAs using automated software.

View Article and Find Full Text PDF

Background: Chagas disease is a systemic illness with widespread microvascular involvement. Experimental and clinical studies suggest that functional and structural microcirculatory abnormalities might be relevant to the disease progression.

Objectives: To show the presence of sublingual microcirculatory alterations in patients with chronic Chagas disease.

View Article and Find Full Text PDF

Objective: To compare the trueness of incisal guidance of implant-supported single crowns designed by patient-specific motion (PSM) with that designed by average-value virtual articulator (AVA).

Methods: The study had recruited 12 participants with complete dentition and stable incisal guidance. An intraoral scanner was used to scan digital casts and record two types of patient-specific motion (data only including protrusive movement, and data including protrusive movement and lateral protrusive movement).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!