A technical description of uterovaginal and rectal applicator system of manual afterloading is described. A simple solution while using domestic materials covering the requirements of present-day brachytherapy. The applicators proved to be suitable for gamma radiation sources as well as for gamma-neutron radiation of 252Cf sources.

Download full-text PDF

Source

Publication Analysis

Top Keywords

[manual afterloading
4
afterloading applicators
4
applicators intracavitary
4
intracavitary brachytherapy]
4
brachytherapy] technical
4
technical description
4
description uterovaginal
4
uterovaginal rectal
4
rectal applicator
4
applicator system
4

Similar Publications

A case report of non-classical treatment choice for mycosis fungoides (MF) presented on the left upper eyelid and forehead. Superficial brachytherapy using 3D technique was prescribed to preserve the lens's functionality, and successfully eliminate malignant lesion. Treatment was conducted with high-dose-rate (HDR) brachytherapy using iridium-192 (Ir) source as a base and Flexitron device as an afterloader.

View Article and Find Full Text PDF
Article Synopsis
  • - Hemorrhage is the main cause of preventable death in trauma situations, leading to military and civilian advancements in medical practices, particularly through the use of tourniquets to manage extremity bleeding and save lives.
  • - While tourniquets have significantly decreased deaths from bleeding in military settings, noncompressible hemorrhage still poses a major risk, especially before patients receive definitive medical care.
  • - The study explores using a small, disposable pressure monitor during resuscitative endovascular balloon occlusion of the aorta (REBOA) to enhance blood pressure monitoring, facilitate better resuscitation practices, and reduce the need for blood products in extreme environments.
View Article and Find Full Text PDF

Background: Comprehensive quality assurance (QA) for a seamless workflow of high-dose-rate brachytherapy, from imaging to planning and irradiation, is uncommon, and QA of the source dwell position is performed in one- or two-dimensions. Gel dosimetry using magnetic resonance imaging (MRI) is effective in verifying the three-dimensional distribution of doses for image-guided brachytherapy (IGBT). However, MRI scanners are not readily accessible, and MRI scanning is time-consuming.

View Article and Find Full Text PDF

Background: Electromagnetic Tracking (EMT) technology has been integrated in a prototype high-dose-rate brachytherapy (HDR-BT) afterloading device. Its potential for dwell position (DP) monitoring has earlier been demonstrated in prostate phantoms. However, its performance for prostate BT in the clinical setting remains to be assessed.

View Article and Find Full Text PDF

Accuracy of an electromagnetic tracking enabled afterloader based on the automated registration with CT phantom images.

Med Phys

February 2024

Département de physique, de génie physique et d'optique, et Centre de recherche sur le cancer, Université Laval, Québec, Québec, Canada.

Background: Electromagnetic tracking (EMT) has been researched for brachytherapy applications, showing a great potential for automating implant reconstruction, and overcoming image-based limitations such as contrast and spatial resolution. One of the challenges of this technology is that it does not intrinsically share the same reference frame as the patient's medical imaging.

Purpose: To present a novel phantom that can be used for a comprehensive quality assurance (QA) program of brachytherapy EMT systems and use this phantom to validate a novel applicator-based registration method of EMT and image reference frames for gynecological (GYN) interstitial brachytherapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!