Influence of Glenosphere Design on Outcomes and Complications of Reverse Arthroplasty: A Systematic Review.

Clin Orthop Surg

Department of Orthopaedic Surgery, Rothman Institute, Thomas Jefferson University, Philadelphia, PA, USA.

Published: September 2016

Background: Different implant designs are utilized in reverse shoulder arthroplasty. The purpose of this systematic review was to evaluate the results of reverse shoulder arthroplasty using a traditional (Grammont) prosthesis and a lateralized prosthesis for the treatment of cuff tear arthropathy and massive irreparable rotator cuff tears.

Methods: A systematic review of the literature was performed via a search of two electronic databases. Two reviewers evaluated the quality of methodology and retrieved data from each included study. In cases where the outcomes data were similar between studies, the data were pooled using frequency-weighted mean values to generate summary outcomes.

Results: Thirteen studies met the inclusion and exclusion criteria. Demographics were similar between treatment groups. The frequency-weighted mean active external rotation was 24° in the traditional group and 46° in the lateralized group (p = 0.0001). Scapular notching was noted in 44.9% of patients in the traditional group compared to 5.4% of patients in the lateralized group (p = 0.0001). The rate of clinically significant glenoid loosening was 1.8% in the traditional group and 8.8% in the lateralized group (p = 0.003).

Conclusions: Both the traditional Grammont and the lateralized offset reverse arthroplasty designs can improve pain and function in patients with diagnoses of cuff tear arthropathy and irreparable rotator cuff tear. While a lateralized design can result in increased active external rotation and decreased rates of scapular notching, there may be a higher rate of glenoid baseplate loosening.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4987313PMC
http://dx.doi.org/10.4055/cios.2016.8.3.288DOI Listing

Publication Analysis

Top Keywords

systematic review
12
cuff tear
12
traditional group
12
lateralized group
12
reverse arthroplasty
8
reverse shoulder
8
shoulder arthroplasty
8
traditional grammont
8
tear arthropathy
8
irreparable rotator
8

Similar Publications

TiRobot-assisted versus freehand femoral neck system placement in the treatment of femoral neck fractures: a systematic review and meta-analysis.

J Robot Surg

January 2025

The Third Ward of Orthopaedic Department, General Hospital of Ningxia Medical University, 804 Shengli South Street, Hui Autonomous Region, Yinchuan, Ningxia, 750004, People's Republic of China.

The purpose of this study is to assess the safety and effectiveness of TiRobot-assisted treatment for femoral neck fractures, in comparison to traditional freehand treatment methods. Throughout the research process, we conducted an extensive literature search across numerous databases, including PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), CQVIP, and Wanfang. Based on the literature screening criteria, we selected six studies, encompassing 358 cases of femoral neck fracture patients, for this meta-analysis.

View Article and Find Full Text PDF

Introduction: Laryngeal chondrosarcoma (CS) is a rare indolent malignant tumor. High-grade (G3), dedifferentiated (DD), and myxoid (MY) CSs are considered more aggressive subtypes due to their metastatic potential and relatively poor outcomes. The aim of this systematic review is to evaluate treatment modalities and survival outcomes in patients affected by these rarer CS subtypes.

View Article and Find Full Text PDF

Background: Patellar instability is frequently encountered by orthopaedic surgeons. One of the major risk factors of this condition is underlying trochlear dysplasia (TD). Recent trends have indicated the use of multiple procedures to correct patellar instability under these conditions.

View Article and Find Full Text PDF

Background: Knee injuries resulting in purely cartilaginous defects are rare, and controversy remains regarding the reliability of chondral-only fixation.

Purpose: To systematically review the literature for fixation methods and outcomes after primary fixation of chondral-only defects within the knee.

Study Design: Systematic review; Level of evidence, 5.

View Article and Find Full Text PDF

Background: Selective androgen receptor modulators (SARMs) are small-molecule compounds that exert agonist and antagonist effects on androgen receptors in a tissue-specific fashion. Because of their performance-enhancing implications, SARMs are increasingly abused by athletes. To date, SARMs have no Food and Drug Administration approved use, and recent case reports associate the use of SARMs with deleterious effects such as drug-induced liver injury, myocarditis, and tendon rupture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!