Background: There are limited data on the incidence, clinical implications, and predisposing factors of transcatheter heart valve (THV) thrombosis following transcatheter aortic valve replacement (TAVR).

Objectives: The authors assessed the incidence, potential predictors, and clinical implications of THV thrombosis as determined by contrast-enhanced multidetector computed tomography (MDCT) after TAVR.

Methods: Among 460 consecutive patients who underwent TAVR with the Edwards Sapien XT or Sapien 3 (Edwards Lifesciences, Irvine, California) THV, 405 (88%) underwent MDCT in addition to transthoracic and transesophageal echocardiography 1 to 3 months post-TAVR. MDCT scans were evaluated for hypoattenuated leaflet thickening that indicated THV thrombosis.

Results: MDCT verified THV thrombosis in 28 of 405 (7%) patients. A total of 23 patients had subclinical THV thrombosis, whereas 5 (18%) patients experienced clinically overt obstructive THV thrombosis. THV thrombosis risk did not differ among different generations of THVs (8% vs. 6%; p = 0.42). The risk of THV thrombosis in patients who did not receive warfarin was higher compared with patients who received warfarin (10.7% vs. 1.8%; risk ratio [RR]: 6.09; 95% confidence interval [CI]: 1.86 to 19.84). A larger THV was associated with an increased risk of THV thrombosis (p = 0.03). In multivariable analysis, a 29-mm THV (RR: 2.89; 95% CI: 1.44 to 5.80) and no post-TAVR warfarin treatment (RR: 5.46; 95% CI: 1.68 to 17.7) independently predicted THV thrombosis. Treatment with warfarin effectively reverted THV thrombosis and normalized THV function in 85% of patients as documented by follow-up transesophageal echocardiography and MDCT.

Conclusions: Incidence of THV thrombosis in this large study was 7%. A larger THV size may predispose to THV thrombosis, whereas treatment with warfarin appears to have a protective effect. Although often subclinical, THV thrombosis may have important clinical implications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2016.08.010DOI Listing

Publication Analysis

Top Keywords

thv thrombosis
44
thv
17
clinical implications
16
thrombosis
12
transcatheter aortic
8
aortic valve
8
predisposing factors
8
transesophageal echocardiography
8
risk thv
8
larger thv
8

Similar Publications

Benchtop Flow Stasis Quantification: In Vitro Methods and In Vivo Possibilities.

Cardiovasc Eng Technol

December 2024

Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, GA, 30313-2412, USA.

Article Synopsis
  • Neo-sinus flow stasis has been linked to the severity of transcatheter heart valve thrombosis, and traditional assessment methods often face challenges due to limited optical access.
  • This study introduces and compares laser-enhanced video densitometry (LEVD) and fluoroscopic video densitometry (FVD) to evaluate flow stasis, proposing a new metric called contrast attenuation ratio (CAR) as an effective measure.
  • Results show strong correlation between CAR and traditional measures, indicating CAR's practicality for assessing flow stasis from routine clinical fluoroscopic data.
View Article and Find Full Text PDF

Background: Research on the role of transcatheter heart valve (THV) deformation and calcium distribution in patients with bicuspid aortic valves (BAVs) undergoing transcatheter aortic valve replacement (TAVR) remains limited.

Objectives: The aim of this study was to evaluate the impact of THV deformation on clinical outcomes in individuals with BAVs undergoing TAVR and the influence of calcium on these outcomes.

Methods: In total, 229 consecutive patients with BAVs who underwent TAVR with balloon-expandable valves and had computed tomography (CT) performed 30 days post-TAVR were analyzed.

View Article and Find Full Text PDF

[How to deal with elevated gradient following TAVR?].

Ann Cardiol Angeiol (Paris)

September 2024

Institut Cardiovasculaire Paris Sud, Hôpital Privé Jacques Cartier, Ramsay Santé, 91300, Massy, France. Electronic address:

Over the past two decades, transcatheter aortic valve implantation (TAVI) has become a safe and effective therapeutic option for symptomatic and severe aortic stenosis, regardless of the surgical risk spectrum. With the expansion of TAVI indications to low-risk and younger patients, it is crucial to ensure satisfactory and durable hemodynamic outcomes to guarantee transcatheter heart valve (THV) longevity. However, secondary THV dysfunction may occur, often manifested by an increased transvalvular gradient.

View Article and Find Full Text PDF

Subclinical leaflet thrombus in patients with severe aortic stenosis and atrial fibrillation -ENRICH-AF TAVI study.

Sci Rep

June 2024

Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo Chuo-ku, Kumamoto, 860-8556, Japan.

Article Synopsis
  • Subclinical leaflet thrombosis (SLT) can lead to failure of transcatheter heart valves (THV) after TAVI, prompting this study to investigate its formation and related thrombotic factors.
  • In a study of 26 patients treated with edoxaban for atrial fibrillation undergoing TAVI, SLT was observed in 16.7% of patients at one week, decreasing to 5.9% by three months.
  • It was found that patients with SLT at one week had reduced maximal leaflet thickness, while thrombogenicity initially dropped but began to rise again by three months post-TAVI, indicating complex dynamics in thrombus formation in the early recovery phase.
View Article and Find Full Text PDF

Cardiac computed tomography post-transcatheter aortic valve replacement.

J Cardiovasc Comput Tomogr

July 2024

Department of Cardiology, Fiona Stanley Hospital, Perth, Australia; Harry Perkins Institute of Medical Research, Perth, Australia; Medical School, Curtin University, Perth, Australia. Electronic address:

Transcatheter aortic valve replacement (TAVR) is performed to treat aortic stenosis and is increasingly being utilised in the low-to-intermediate-risk population. Currently, attention has shifted towards long-term outcomes, complications and lifelong maintenance of the bioprosthesis. Some patients with TAVR in-situ may develop significant coronary artery disease over time requiring invasive coronary angiography, which may be problematic with the TAVR bioprosthesis in close proximity to the coronary ostia.

View Article and Find Full Text PDF