Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Inhaled drugs are the mainstay of treatment for lung diseases such as asthma and chronic obstructive pulmonary disease. However, failure to use inhalation devices correctly can lead to a poorly controlled status. A vast number of inhalation devices exist and each device has specific requirements to achieve optimum inhalation of the drug. Currently, there is no overview of inhalation requirements considering all devices. This article presents a review of the literature on different inhalation device requirements and incorporates the data into a new inhalation flow algorithm.
Methods: Data from literature on commercially available inhalation devices were evaluated and parameters, such as inhalation flow rate, flow acceleration, inhalation volume, and inspiration time assessed for the required inhalation maneuver specific to the device. All agreed upon data points were used to develop an inhalation flow algorithm.
Results: The literature analysis revealed availability of robust data for the required inhalation flow characteristics for most devices and thus for the development of an algorithm. For those devices for which these parameters are not published, the minimum required flow criteria were defined based on published data regarding individual aspects of aerosol quality.
Conclusions: This review provides an overview of inhalation devices available on the market regarding requirements for an acceptable inhalation maneuver and shows which goals should be achieved in terms of inhalation flows. The presented algorithm can be used to develop a new computer based measurement system which could help to test and train patients' individual inhalation maneuvers with their inhalation devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.rmed.2016.07.013 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!