A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inhalation device requirements for patients' inhalation maneuvers. | LitMetric

Inhalation device requirements for patients' inhalation maneuvers.

Respir Med

Mundipharma GmbH, Germany. Electronic address:

Published: September 2016

Background: Inhaled drugs are the mainstay of treatment for lung diseases such as asthma and chronic obstructive pulmonary disease. However, failure to use inhalation devices correctly can lead to a poorly controlled status. A vast number of inhalation devices exist and each device has specific requirements to achieve optimum inhalation of the drug. Currently, there is no overview of inhalation requirements considering all devices. This article presents a review of the literature on different inhalation device requirements and incorporates the data into a new inhalation flow algorithm.

Methods: Data from literature on commercially available inhalation devices were evaluated and parameters, such as inhalation flow rate, flow acceleration, inhalation volume, and inspiration time assessed for the required inhalation maneuver specific to the device. All agreed upon data points were used to develop an inhalation flow algorithm.

Results: The literature analysis revealed availability of robust data for the required inhalation flow characteristics for most devices and thus for the development of an algorithm. For those devices for which these parameters are not published, the minimum required flow criteria were defined based on published data regarding individual aspects of aerosol quality.

Conclusions: This review provides an overview of inhalation devices available on the market regarding requirements for an acceptable inhalation maneuver and shows which goals should be achieved in terms of inhalation flows. The presented algorithm can be used to develop a new computer based measurement system which could help to test and train patients' individual inhalation maneuvers with their inhalation devices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rmed.2016.07.013DOI Listing

Publication Analysis

Top Keywords

inhalation devices
20
inhalation
19
inhalation flow
16
inhalation device
8
device requirements
8
inhalation maneuvers
8
devices
8
overview inhalation
8
required inhalation
8
inhalation maneuver
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!