A high-powered argon blue-green laser coupled to a 300-microns quartz fiberoptic probe was used to create an ab interno sclerostomy in a patient undergoing enucleation for a blind painful eye. Despite the presence of diffuse rubeosis, 360 degrees peripheral anterior synechiae, and superior conjunctival scarring, it was possible to create a full-thickness defect from the anterior chamber angle to the subconjunctival space without operative complications. Six laser applications were required using 8 W of power per pulse and 0.1-second pulse duration. The eye was enucleated immediately after the laser procedure, prepared for light microscopy, and sectioned serially. Histologic analysis demonstrated a patent fistula approximately 300 microns in diameter with sharp wound margins. Tissue damage was localized to within 150 microns of the sclerostomy. The overlying conjunctiva was intact.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archopht.1989.01070020249034DOI Listing

Publication Analysis

Top Keywords

interno sclerostomy
8
high-powered argon
8
sclerostomy high-powered
4
argon endolaser
4
endolaser clinicopathologic
4
clinicopathologic correlation
4
correlation high-powered
4
argon blue-green
4
blue-green laser
4
laser coupled
4

Similar Publications

Background: To evaluate the safety and efficacy of the Minimally Invasive Micro Sclerotomy (MIMS) procedure in the management of uncontrolled open-angle glaucoma.

Methods: A prospective, open-label, single-arm clinical evaluation with intra-subject comparisons performed at the Ophthalmologic Center after S.V.

View Article and Find Full Text PDF

Objective: To describe the 3-year outcomes of patients who underwent ab interno trabeculectomy revision with a translimbal sclerostomy spatula augmented with 5-flourouracil.

Design: Retrospective cohort study.

Participants: In this single-centre study, inclusion criteria included patients who were 18 years of age or older with advanced glaucoma who had undergone ab interno trabeculectomy revision with 5-flourouracil due to subconjunctival fibrosis and above-target intraocular pressure (IOP).

View Article and Find Full Text PDF

Prcis: Intermediate-term results suggest that ab interno Minimally Invasive Micro Sclerostomy (MIMS) stent-less subconjunctival filtration procedure is a promising treatment option for patients with open-angle glaucoma (OAG).

Purpose: MIMS is a novel ab interno, stent-less, subconjunctival filtration procedure. This study set to investigate the safety, performance, and efficacy of MIMS in OAG patients.

View Article and Find Full Text PDF

Er:YAG laser-assisted filtration surgery: initial results in rabbits.

BMC Ophthalmol

May 2021

Sam Rothberg Glaucoma Center, Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel, affiliated to the Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv, Israel.

Background: Glaucoma is a leading cause of global blindness, especially preventable blindness. The increased prevalence of glaucoma has led to a growing demand for newer, safer, more rapid, and simpler treatments for the reduction of intraocular pressure (IOP). In this study, we evaluated the safety and feasibility of performing filtration glaucoma surgery with an Ab-Interno Er:YAG laser in rabbits.

View Article and Find Full Text PDF

Introduction: This study evaluates long-term outcomes of two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin in eyes with refractory open angle glaucoma (OAG).

Methods: Prospective ongoing 5-year study of 80 eligible subjects (70 with 4-year follow-up) with OAG and IOP ≥ 18 mmHg after prior trabeculectomy and while taking 1-3 glaucoma medications. Subjects received two iStent trabecular micro-bypass stents, one iStent Supra suprachoroidal stent, and postoperative travoprost.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!