A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cataracts induced by neodymium-yttrium-aluminium-garnet laser lysis of vitreous floaters. | LitMetric

Background: Neodymium-yttrium-aluminium-garnet (Nd:YAG) laser vitreolysis has been proposed as a treatment modality for symptomatic vitreous floaters. The purpose of this paper is to report two cases of cataracts associated with posterior capsular compromise, induced by Nd:YAG laser vitreolysis for symptomatic vitreous floaters.

Method: Case series.

Results: Two patients who underwent ND:YAG laser vitreolysis for symptomatic floaters, presented with decline in visual acuity in the treated eye after the laser procedure. At the slit-lamp biomicroscope, each patient was found to have a posterior subcapsular cataract in the treated eye, with obvious loss of integrity of the posterior capsule. These two patients underwent cataract extraction by the same surgeon via phacoemulsification. Both eyes were found to have a defect in the posterior capsule intraoperatively. In both cases, a three-piece acrylic intraocular lens implant was placed in the sulcus, achieving optic capture. The best-corrected visual acuity (BCVA) was 20/20 in both patients, at 1 month following the surgery. At 2 months, one patient had a BCVA of 20/15. The second patient maintained a BCVA of 20/20 at 3 months.

Conclusions: Secondary cataract formation accompanied by loss of integrity of the posterior capsule is a potential complication of Nd:YAG laser vitreolysis for symptomatic floaters.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjophthalmol-2016-309005DOI Listing

Publication Analysis

Top Keywords

ndyag laser
16
laser vitreolysis
16
vitreolysis symptomatic
12
posterior capsule
12
vitreous floaters
8
symptomatic vitreous
8
patients underwent
8
symptomatic floaters
8
visual acuity
8
treated eye
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!