Rate-weakening friction characterizes both slow sliding and catastrophic failure of landslides.

Proc Natl Acad Sci U S A

Department of Geological and Environmental Sciences, Stanford University, Stanford, CA 94305.

Published: September 2016

Catastrophic landslides cause billions of dollars in damages and claim thousands of lives annually, whereas slow-moving landslides with negligible inertia dominate sediment transport on many weathered hillslopes. Surprisingly, both failure modes are displayed by nearby landslides (and individual landslides in different years) subjected to almost identical environmental conditions. Such observations have motivated the search for mechanisms that can cause slow-moving landslides to transition via runaway acceleration to catastrophic failure. A similarly diverse range of sliding behavior, including earthquakes and slow-slip events, occurs along tectonic faults. Our understanding of these phenomena has benefitted from mechanical treatments that rely upon key ingredients that are notably absent from previous landslide descriptions. Here, we describe landslide motion using a rate- and state-dependent frictional model that incorporates a nonlocal stress balance to account for the elastic response to gradients in slip. Our idealized, one-dimensional model reproduces both the displacement patterns observed in slow-moving landslides and the acceleration toward failure exhibited by catastrophic events. Catastrophic failure occurs only when the slip surface is characterized by rate-weakening friction and its lateral dimensions exceed a critical nucleation length [Formula: see text] that is shorter for higher effective stresses. However, landslides that are extensive enough to fall within this regime can nevertheless slide slowly for months or years before catastrophic failure. Our results suggest that the diversity of slip behavior observed during landslides can be described with a single model adapted from standard fault mechanics treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5027430PMC
http://dx.doi.org/10.1073/pnas.1607009113DOI Listing

Publication Analysis

Top Keywords

catastrophic failure
16
slow-moving landslides
12
landslides
9
rate-weakening friction
8
catastrophic
6
failure
6
friction characterizes
4
characterizes slow
4
slow sliding
4
sliding catastrophic
4

Similar Publications

Background: Transcatheter valve-in-valve replacement (TMViVR) is an alternative option for patients with bioprosthetic valve failure (BVF) who are at high surgical risk. Although infective endocarditis (IE) after transcatheter mitral valve-in-valve replacement is unusual, it is associated with significantly high mortality.

Case Presentation: An 81-year-old male patient was admitted with intermittent thoracic tightness, chest pain persisting for 3 years, and shortness of breath with nausea for 1 week.

View Article and Find Full Text PDF

The failure of locked-segment landslides is associated with the destruction of locked segments that exhibit an energy accumulation effect. Thus, understanding their failure mode and instability mechanism for landslide hazard prevention and control is critical. In this paper, multiple instruments, such as tilt sensors, pore water pressure gauges, moisture sensors, matrix suction sensors, resistance strain gauges, miniature earth pressure sensors, a three-dimensional (3D) laser scanner, and a camera, were used to conduct the physical model tests on the rainfall-induced arch locked-segment landslide to analyze the resulting tilting deformation and evolution mechanism.

View Article and Find Full Text PDF

Structural fatigue can lead to catastrophic failures in various engineering applications and must be properly monitored and effectively managed. This paper provides a state-of-the-art review of recent developments in structural fatigue monitoring using piezoelectric-based sensors. Compared to alternative sensing technologies, piezoelectric sensors offer distinct advantages, including compact size, lightweight design, low cost, flexible formats, and high sensitivity to dynamic loads.

View Article and Find Full Text PDF

Bionic Inner-Tapered Energy Absorption Tube Featuring Progressively Enhanced Fold Deformation Mode.

Biomimetics (Basel)

December 2024

Key Laboratory of Bionic Engineering, Ministry of Education, Jilin University, Changchun 130022, China.

Slender tubes are in high demand owing to their lightweight and outstanding energy absorption. However, conventional slender tubes are prone to catastrophic failures such as Euler's buckling under axial load. Interestingly, growing bamboos overcome this similar dilemma via a unique tapered intine in the internodes, which endows them with excellent energy absorption.

View Article and Find Full Text PDF

The current research aims to analyze the shape and structural features of the eggs of the lepidoptera species sp. (Lepidoptera, Nympalidae) and develop design solutions through the implementation of a novel strategy of biomimetic design. Scanning electron microscopy (SEM) analysis of the chorion reveals a medial zone that forms an arachnoid grid resembling a ribbed dome with convex longitudinal ribs and concave transverse ring members.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!