Assessment of Imaging Modalities and Response Metrics in Ewing Sarcoma: Correlation With Survival.

J Clin Oncol

Vadim S. Koshkin, Cleveland Clinic, Cleveland, OH; Vanessa Bolejack, Cancer Research and Biostatistics, Seattle, WA; Lawrence H. Schwartz, Binsheng Zhao, Columbia University Medical Center, New York, NY; Richard L. Wahl, Mallinckrodt Institute of Radiology, Washington University in St Louis, St Louis, MO; Rashmi Chugh, Scott M. Schuetze, Laurence H. Baker, University of Michigan Medical School; Denise K. Reinke, Sarcoma Alliance for Research Through Collaboration, Ann Arbor, MI; Joo H. O, The Catholic University of Korea; Seoul St Mary's Hospital, Seoul, Republic of Korea; and Shreyaskumar R. Patel, The University of Texas MD Anderson Cancer Center, Houston, TX.

Published: October 2016

Purpose: Despite the rapidly increasing use of [F]fluorodeoxyglucose (FDG) -positron emission tomography (PET), the comparison of anatomic and functional imaging in the assessment of clinical outcomes has been lacking. In addition, there has not been a rigorous evaluation of how common radiologic criteria or the location of the radiology reader (local v central) compare in the ability to predict benefit. In this study, we aimed to compare the effectiveness of various radiologic response assessments for the prediction of overall survival (OS) within the same data set of patients with sarcoma.

Methods: We analyzed assessments made during a clinical trial of a novel IGF1R antibody in Ewing sarcoma: PET Response Criteria in Solid Tumors (PERCIST) for functional imaging and WHO criteria (performed locally and centrally), RECIST, and volumetric analysis for anatomic imaging. We compared the effectiveness of the various criteria for the prediction of progression and survival.

Results: For volume analysis, progression-defined as cumulative lesion volume increase of 100% at 6 weeks-was the optimal cutoff for decreased OS (P < .001). Assessment of the day-9 FDG-PET scan was associated with reduced OS in progressors compared with nonprogressors (P = .001) and with improved OS in responders compared with nonresponders. Significant variations in response (18% to 44%) and progression (9% to 50%) were observed between the different criteria. The comparison of central and local interpretation of anatomic imaging produced similar outcomes. PET was superior to anatomic imaging in identification of a response. Volume analysis identified the most responders among the anatomic imaging criteria.

Conclusion: An early signal with FDG-PET on day 9 and volume analysis were the best predictors of benefit. Validation of the volumetric analysis is required.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5065114PMC
http://dx.doi.org/10.1200/JCO.2016.68.1858DOI Listing

Publication Analysis

Top Keywords

anatomic imaging
16
volume analysis
12
ewing sarcoma
8
functional imaging
8
volumetric analysis
8
imaging
6
response
5
anatomic
5
criteria
5
analysis
5

Similar Publications

Analysis of the symmetry of the brain hemispheres at the level of individual structures and dominant tissue features has been the subject of research for many years in the context of improving the effectiveness of imaging methods for the diagnosis of brain tumor, stroke, and Alzheimer's disease, among others. One useful approach is to reliably determine the midline of the brain, which allows comparative analysis of the hemispheres and uncovers information on symmetry/asymmetry in the relevant planes of, for example, CT scans. Therefore, an effective method that is robust to various geometric deformations, artifacts, varying noise characteristics, and natural anatomical variability is sought.

View Article and Find Full Text PDF

Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.

View Article and Find Full Text PDF

Intravascular ultrasound (IVUS) provides precise anatomic information in coronary arteries including quantitative measurements and morphological assessment. To standardize the IVUS analysis in the current era, this updated expert consensus document summarizes the methods of measurements and assessment of IVUS images and the clinical evidence of IVUS use in percutaneous coronary intervention.

View Article and Find Full Text PDF

Objectives: To develop and validate a lesion-based grading system using clinicopathological and MRI features for predicting positive surgical margin (PSM) following robotic-assisted laparoscopic prostatectomy (RALP) among prostate cancer (PCa) patients.

Methods: Consecutive MRI examinations of patients undergoing RALP for PCa were retrospectively collected from two medical institutions. Patients from center 1 undergoing RALP between January 2020 and December 2021 were included in the derivation cohort and those between January 2022 and December 2022 were allocated to the validation cohort.

View Article and Find Full Text PDF

Relationship between functional structures and horizontal connections in macaque inferior temporal cortex.

Sci Rep

January 2025

Department of Neurosurgery of the Second Affiliated Hospital, Interdisciplinary Institute of Neuroscience and Technology, School of Medicine, Zhejiang University, Hangzhou, China.

Horizontal connections in anterior inferior temporal cortex (ITC) are thought to play an important role in object recognition by integrating information across spatially separated functional columns, but their functional organization remains unclear. Using a combination of optical imaging, electrophysiological recording, and anatomical tracing, we investigated the relationship between stimulus-response maps and patterns of horizontal axon terminals in the macaque ITC. In contrast to the "like-to-like" connectivity observed in the early visual cortex, we found that horizontal axons in ITC do not preferentially connect sites with similar object selectivity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!