Download full-text PDF

Source

Publication Analysis

Top Keywords

[hemodynamic effects
4
effects amrinone
4
amrinone comparison
4
comparison dobutamine
4
dobutamine patients
4
patients chronic
4
chronic respiratory
4
respiratory insufficiency
4
insufficiency pulmonary
4
pulmonary hypertension]
4

Similar Publications

Increased blood pressure upon standing is considered a cardiovascular risk factor. We investigated the reproducibility of changes in aortic blood pressure, heart rate, stroke volume, cardiac output, and systemic vascular resistance during three passive head-up tilts (HUT) in 223 participants without cardiovascular medications (mean age 46 years, BMI 28 kg/m2, 54% male). Median time gap between the first and the second HUT was 9 weeks and the second and the third HUT 4 weeks.

View Article and Find Full Text PDF

Carbon dioxide gas emboli is a potentially fatal complication that occurs more frequently during laparoscopic hepatectomy compared to other laparoscopic surgeries. The patient featured in this report had massive gas embolism confirmed by intraoperative transesophageal echocardiography (TEE) that were associated with episodes of severe hypoxemia, hemodynamic instability, and right ventricular failure requiring conversion to open hepatectomy. Abrupt abdominal decompression resulted in massive hemorrhage from a previously undetected defect in the middle hepatic vein.

View Article and Find Full Text PDF

Background: Heart failure with preserved ejection fraction (HFpEF) is linked to prolonged endoplasmic reticulum (ER) stress. P21-activated kinase 2 (Pak2) facilitates a protective ER stress response. This study explores the mechanism and role of Pak2 in HFpEF pathology.

View Article and Find Full Text PDF

A thrombus straddling a patent foramen ovale (TSPFO) is a rare condition that presents significant health risks, including stroke or myocardial infarction, and can be life-threatening if not promptly addressed. We report the case of a 42-year-old female with morbid obesity who presented with sudden shortness of breath due to a bilateral pulmonary embolism. Imaging revealed a thrombus extending from the right atrium to the left atrium through the patent foramen ovale (PFO).

View Article and Find Full Text PDF

Context: Heart rate (HR) is the most vital parameter to assess hemodynamic transition at birth. ECG is considered a gold standard for HR assessment. New devices with dry electrodes are easy to apply on a wet newborn.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!