A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure. | LitMetric

Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure.

N Engl J Med

From the Department of Cardiology, Rigshospitalet (L.K., J.J.T., F.G., R.V., C.H., J.H.S., D.E.H., S.P.), and the Department of Cardiology, Bispebjerg Hospital (J.J.T.), University of Copenhagen, Copenhagen; the Department of Cardiology, Aarhus University Hospital, Aarhus (J.C.N., H.E.); the Department of Cardiology, Herlev and Gentofte Hospital, University of Copenhagen, Hellerup (J.H., N.E.B.); the Department of Cardiology, Odense University Hospital, Odense (L.V., A.B.); the Department of Cardiology, Aalborg University Hospital (E.K., A.M.T., C.T.-P.), and the Clinical Institute, Aalborg University (N.E.B.), Aalborg; the Department of Cardiology, Zealand University Hospital, Roskilde (G.J.); Frederiksberg Heart Clinic, Frederiksberg (P.H.); the Department of Cardiology, Lillebaelt Hospital, Vejle (F.H.S.); and the Department of Cardiology, Odense University Hospital, Svendborg (K.E.) - all in Denmark.

Published: September 2016

AI Article Synopsis

  • The study investigated the impact of implantable cardioverter-defibrillators (ICDs) on patients with symptomatic systolic heart failure not caused by coronary artery disease, comparing ICD treatment with usual clinical care.
  • A total of 1,116 patients were enrolled, and after 67.6 months, it was found that ICDs did not significantly lower overall mortality rates compared to the control group, although they did reduce instances of sudden cardiac death.
  • The findings suggest that while ICDs may have benefits for sudden cardiac death prevention, they do not significantly improve long-term survival rates in this specific patient population.

Article Abstract

Background: The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT).

Methods: In a randomized, controlled trial, 556 patients with symptomatic systolic heart failure (left ventricular ejection fraction, ≤35%) not caused by coronary artery disease were assigned to receive an ICD, and 560 patients were assigned to receive usual clinical care (control group). In both groups, 58% of the patients received CRT. The primary outcome of the trial was death from any cause. The secondary outcomes were sudden cardiac death and cardiovascular death.

Results: After a median follow-up period of 67.6 months, the primary outcome had occurred in 120 patients (21.6%) in the ICD group and in 131 patients (23.4%) in the control group (hazard ratio, 0.87; 95% confidence interval [CI], 0.68 to 1.12; P=0.28). Sudden cardiac death occurred in 24 patients (4.3%) in the ICD group and in 46 patients (8.2%) in the control group (hazard ratio, 0.50; 95% CI, 0.31 to 0.82; P=0.005). Device infection occurred in 27 patients (4.9%) in the ICD group and in 20 patients (3.6%) in the control group (P=0.29).

Conclusions: In this trial, prophylactic ICD implantation in patients with symptomatic systolic heart failure not caused by coronary artery disease was not associated with a significantly lower long-term rate of death from any cause than was usual clinical care. (Funded by Medtronic and others; DANISH ClinicalTrials.gov number, NCT00542945 .).

Download full-text PDF

Source
http://dx.doi.org/10.1056/NEJMoa1608029DOI Listing

Publication Analysis

Top Keywords

heart failure
24
systolic heart
20
coronary artery
16
artery disease
16
control group
16
patients
14
patients symptomatic
12
symptomatic systolic
12
caused coronary
12
icd group
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!