Bismuth germanate as a perspective material for dielectric resonators in EPR spectroscopy.

J Magn Reson

International Tomography Center, SB RAS, Novosibirsk 630090, Russia; Novosibirsk State University, Novosibirsk 630090, Russia. Electronic address:

Published: October 2016

High purity bismuth germanate (Bi4(GeO4)3, BGO) is proposed and implemented as an alternative material for dielectric EPR resonators. A significant improvement of the absolute sensitivity can be readily achieved by substituting the alumina insert (ring) by BGO-made one in commercially available X-band EPR probeheads. Four BGO dielectric inserts of 2, 3, 4 and 5mm inner diameter (ID) were made for comparison with standard 5mm inner diameter alumina insert. All inserts were introduced into commercial Bruker EPR resonator ER 4118X-MD-5W1, and their performance was investigated. The Q-values of empty resonators, B1 saturation curves and continuous wave EPR spectra of DPPH (2,2-diphenyl-1-picrylhydrazyl) were measured and analyzed in a temperature range 6-300K. BGO-made resonators were found superior in several important aspects. The background signals arising from BGO are much weaker compared to those of alumina at B=0-0.6T and T=6-300K; this is especially useful for measuring weak signals in the half-field region, as well as those near the central field. Moreover, mechanical properties of BGO allow easy fabrication of dielectric bodies having various shapes and sizes; in particular, small BGO resonators (e.g. ID=2 or 3mm) strongly enhance sensitivity for small samples due to increase of the filling factor. All these advantages have been also inspected in the pulse mode, proving that higher B1 fields and better filling factors can be achieved, contributing to the overall enhancement of the performance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2016.08.009DOI Listing

Publication Analysis

Top Keywords

bismuth germanate
8
material dielectric
8
alumina insert
8
5mm inner
8
inner diameter
8
resonators
5
epr
5
bgo
5
germanate perspective
4
perspective material
4

Similar Publications

Abstract: Prerequisites for the goal of studying long-lived, magnetically confined, electron-positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an drift technique (of a 2- A, 6-eV beam) and "edge injection" (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior.

View Article and Find Full Text PDF

Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF) information for each pair of 511-keV annihilation photons improves effective sensitivity but requires high timing resolution. Hybrid materials that emit both scintillation and Cherenkov photons, such as bismuth germanate (BGO), recently offer the potential for more precise timing information from Cherenkov photons while maintaining adequate energy resolution from scintillation photons.

View Article and Find Full Text PDF

Performance Comparison of DOI-Encoding PET Detectors Based on 1.1-mm Pitch BGO Arrays With Different Reflectors.

IEEE Trans Radiat Plasma Med Sci

March 2024

Department of Biomedical Engineering, University of California at Davis and now is with the Department of Radiology & Biomedical Imaging, University of California at San Francisco, San Francisco, CA, 94107 USA.

Bismuth germanate (BGO)-based positron emission tomography (PET) detectors are potential candidates for low-dose imaging PET scanners, owing to the high stopping power and low background radiation of BGO. In this paper, we compared the performance of two dual-ended readout PET detectors based on 15 × 15 BGO arrays. Both arrays had the same 1.

View Article and Find Full Text PDF

Integrated Optical Waveguide Electric Field Sensors Based on Bismuth Germanate.

Sensors (Basel)

August 2024

School of Mechanical Engineering and Electronic Information, China University of Geosciences, Wuhan 430074, China.

Bismuth germanate (BiGeO, BGO) is a widely used optical sensing material with a high electro-optic coefficient, ideal for optical electric field sensors. Achieving high precision in electric field sensing requires fabricating optical waveguides on BGO. Traditional waveguide writing methods face challenges with this material.

View Article and Find Full Text PDF

The gamma probe is a commonly used detector for localizing sentinel lymph nodes after the injection of radiopharmaceuticals. In recent years, studies have focused on improving the features of gamma probes to achieve more consistent localization of the radiotracer uptake. As part of this effort, a novel gamma probe prototype based on an active shielding was developed, and its characteristics, including sensitivity, resolution and shielding effectiveness, were determined.