Traditionally, proprioception has been assessed with a passive model, in which an external apparatus moves a body segment. Recently, protocols have been developed based on active movements, which are more representative of functional activities. However, even these approaches require expensive testing equipment and the necessity of a visit to a research lab, as there are no commercially available mobile instruments that allow for the assessment of proprioception outside of a laboratory setting. The objective of this study was to demonstrate the validity and feasibility of using a mobile device (iPod Touch) to assess joint position. We conducted a concurrent validity study in the lab (n=9) and a field based study (n=79). The field based study was conducted at the 2012 American Society of Biomechanics meeting in Gainesville, Florida. The results of both studies demonstrate good agreement with our established protocol using a magnetic tracking device, with angular errors decreasing with increasing shoulder flexion angles. The studies demonstrate the validity and feasibility of using mobile devices for assessing motion-based parameters, both inside and outside of a laboratory setting.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2016.07.033 | DOI Listing |
Cureus
December 2024
Department of Orthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Introduction The role of the condylar position in the correct functioning of the stomatognathic system has been the center of the study. Using cone-beam computed tomography (CBCT), this study looked at the three-dimensional (3D) position of the condylar bone in patients from Class I, Class II, Division 1, and Division 2. Materials and methods This cross-sectional, retrospective study was conducted using 102 CBCT records, with 34 records allocated to each category of malocclusion classification, such as dentoskeletal Class I, skeletal Class II, and dental Class II, Division 1 and 2.
View Article and Find Full Text PDFInt J Exerc Sci
December 2024
Department of Sport and Health Sciences, Technical University of Munich, Munich, BY, GERMANY.
In weightlifting, quantitative kinematic analysis is essential for evaluating snatch performance. While marker-based (MB) approaches are commonly used, they are impractical for training or competitions. Markerless video-based (VB) systems utilizing deep learning-based pose estimation algorithms could address this issue.
View Article and Find Full Text PDFJ Exp Orthop
January 2025
Department of Orthopaedic Surgery and Trauma University Center of Montpellier, University of Montpellier Montpellier France.
Purpose: Gap-balanced total knee arthroplasty (TKA) technique relies on initial ligament evaluation, particularly in patient-specific implantation using computer-assisted technologies. This cadaveric study aimed to compare the reproducibility and reliability of medial and lateral gap measurements between manual stress testing and dynamic ligament balancer.
Methods: Initial gap acquisitions were assessed from eight cadaveric knees (four specimens) during the same navigated TKA procedure by five differently skilled surgeons (three seniors and two juniors).
Acta Vet Scand
January 2025
Department of Companion Animal Clinical Sciences, Faculty of Veterinary Medicine, Norwegian University of Life Sciences, Oluf Thesens Vei 30, Ås, Norway.
Background: A lumbosacral transitional vertebra (LTV) is a congenital anomaly of the caudal vertebral column. It has been associated with asymmetrical canine hip dysplasia (CHD) and cauda equina syndrome (CES) in German Shepherd dogs. This retrospective cross-sectional study aims to report the potential influence of asymmetric LTV on pelvic anatomy using ventrodorsal (VD) radiographs.
View Article and Find Full Text PDFSci Rep
January 2025
China Construction Fifth Engineering Division Corp., Ltd., Changsha, 410004, China.
In order to systematically study the bending behavior of the connection joints of the disc-buckle type formwork support, the accurate numerical model of the disc-buckle type connection joints was obtained through the experimental on the bending behavior of the connection joints of the disc-buckle type, and the bending moment-rotation curve of the joints was verified. The analysis of the failure mode and stress distribution of the joints reveals the importance of the bending behavior of each component. By establishing an accurate numerical model of the joint, the accuracy of the bending experiment of the joint was verified, and the parametric analysis of the influence factors such as the depth of the wedge insertion the disk-plate, the initial position of the wedge insertion the disk-plate, the thickness of the wedge, material constitutive of the wedge and the thickness of the disk-plate was carried out to grasp the influence of the relevant parameters on the bending behavior of the joint.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!