Background: Humeral shaft fractures are generally managed with the conventional posterior open reduction and internal fixation (ORIF) or minimally invasive plate osteosynthesis (MIPO). This study was aimed at comparing the outcomes of these surgical techniques in terms of the vascular integrity of the mid-distal humeral shaft.

Methods: Twelve upper limbs were harvested from 6 fresh cadavers. ORIF or MIPO was randomly performed on either side of each pair of limbs. The axillary artery was perfused with a latex-lead tetraoxide red solution to visualize the vascular structures. The vascular integrity of the humerus was examined by plain radiography and dissection. The periosteal filling achieved with each technique was scored and the scores compared.

Results: In each limb, one main nutrient artery entering the mid-distal humeral shaft anteromedially (83.3 %) or medially (16.7 %) was first identified. No case of injury to the main nutrient artery was noted for either surgical technique. Injuries to the accessory nutrient arteries entering the mid-distal humeral shaft from the posterior aspect were absent in the MIPO cases, but occurred in 52.9 % of the ORIF cases. In addition, MIPO was also superior to the open plate technique showed superior periosteal filling than.

Conclusions: Our results showed that the MIPO technique is superior to the ORIF in terms of preserving the vascular integrity of the mid-distal humeral shaft.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5002093PMC
http://dx.doi.org/10.1186/s12891-016-1224-3DOI Listing

Publication Analysis

Top Keywords

mid-distal humeral
20
humeral shaft
20
vascular integrity
12
surgical techniques
8
open reduction
8
reduction internal
8
internal fixation
8
minimally invasive
8
invasive plate
8
plate osteosynthesis
8

Similar Publications

Changes in limb bone diaphyseal structure in chimpanzees during development.

Am J Biol Anthropol

August 2024

Institutional affiliation: Department of Anthropology, California State University Los Angeles, Los Angeles, California, USA.

Objectives: This study tests if femoral and humeral cross-sectional geometry (CSG) and cross-sectional properties (CSPs) in an ontogenetic series of wild-caught chimpanzees (Pan troglodytes ssp.) reflect locomotor behavior during development. The goal is to clarify the relationship between limb bone structure and locomotor behavior during ontogeny in Pan.

View Article and Find Full Text PDF

[Translated article] The use of an anatomical implant compared to a straight LCP decreases extraction in posterior humeral MIPO.

Rev Esp Cir Ortop Traumatol

June 2023

Servicio de Ortopedia y Traumatología, Hospital Italiano de Buenos Aires, Instituto de Ortopedia y Traumatología «Carlos E. Ottolenghi», Potosí, Buenos Aires, Argentina.

Purpose: Posterior MIPO approach in the humerus has been described by using a 4.5mm LCP plate. Although straight plates have shown good results, they have not been designed to adapt to the distal humeral metaphysis.

View Article and Find Full Text PDF

Objectives: This study compares humeral diaphyseal robusticity and asymmetry between Late Holocene hunter-gatherers from Alaska with the goal of reconstructing habitual activity in relation to culture and environment.

Materials And Methods: Ancestral remains from four geographic regions of Alaska were divided into five site groups defined by subsistence strategies and technology: Aleutian Islands, Coastal Bay, Far North Coastal, Inland/Riverine, and Tikeraq. Mid-distal humeral diaphyseal robusticity was quantified using cross-sectional geometric properties standardized by estimated body mass and bone length.

View Article and Find Full Text PDF

The use of an anatomical implant compared to a straight LCP decreases extraction in posterior humeral MIPO.

Rev Esp Cir Ortop Traumatol

February 2023

Servicio de Ortopedia y Traumatología, Hospital Italiano de Buenos Aires, Instituto de Ortopedia y Traumatología «Carlos E. Ottolenghi», Potosí, Buenos Aires, Argentina.

Purpose: Posterior MIPO approach in the humerus has been described by using a 4.5mm LCP plate. Although straight plates have shown good results, they have not been designed to adapt to the distal humeral metaphysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!