Graphene is a highly promising material in the development of new photodetector technologies, in particular due its tunable optoelectronic properties, high mobilities and fast relaxation times coupled to its atomic thinness and other unique electrical, thermal and mechanical properties. Optoelectronic applications and graphene-based photodetector technology are still in their infancy, but with a range of device integration and manufacturing approaches emerging this field is progressing quickly. In this review we explore the potential of graphene in the context of existing single photon counting technologies by comparing their performance to simulations of graphene-based single photon counting and low photon intensity photodetection technologies operating in the visible, terahertz and X-ray energy regimes. We highlight the theoretical predictions and current graphene manufacturing processes for these detectors. We show initial experimental implementations and discuss the key challenges and next steps in the development of these technologies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038629PMC
http://dx.doi.org/10.3390/s16091351DOI Listing

Publication Analysis

Top Keywords

photon counting
12
single photon
8
graphene-based low
4
low intensity
4
photon
4
intensity photon
4
counting photodetector
4
photodetector graphene
4
graphene highly
4
highly promising
4

Similar Publications

Introduction: The use of urine cytobacteriological examination is a common and essential practice in medicine which helps guide therapeutic management in case of urinary tract infection. The cytological examination of urine samples can be done using the manual (microscopic) or automated technique. The automated approach, which involves the use of artificial intelligence, is faster, more reliable, and more efficient for laboratories.

View Article and Find Full Text PDF

Background: Photon-counting detector (PCD) technology has the potential to reduce noise in computed tomography (CT). This study aimed to carry out a voxelwise noise characterization for a clinical PCD-CT scanner with a model-based iterative reconstruction algorithm (QIR).

Methods: Forty repeated axial acquisitions (tube voltage 120 kV, tube load 200 mAs, slice thickness 0.

View Article and Find Full Text PDF

The rapid advancement of quantum key distribution technology in recent years has spurred significant innovation within the field. Nevertheless, a crucial yet frequently underexplored challenge involves the comprehensive evaluation of security quantum state modulation. To address this issue, we propose a novel framework for quantum group key distribution.

View Article and Find Full Text PDF

Artifact Reduction in Interventional Devices Using Virtual Monoenergetic Images and Iterative Metal Artifact Reduction on Photon-Counting Detector CT.

Invest Radiol

January 2025

From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany (Y.C.L., N.M., P.A.K., A.I., T.D., J.A.L., D.K.); and Siemens Healthineers AG, Erlangen, Germany (S.F., V.H., B.S.).

Objectives: The aim of this study was to assess the impact of an iterative metal artifact reduction (iMAR) algorithm combined with virtual monoenergetic images (VMIs) for artifact reduction in photon-counting detector computed tomography (PCDCT) during interventions.

Materials And Methods: Using an abdominal phantom, we conducted evaluations on the efficacy of iMAR and VMIs for mitigating image artifacts during interventions on a PCDCT. Four different puncture devices were employed under 2 scan modes (QuantumSn at 100 kV, Quantumplus at 140 kV) to simulate various clinical scenarios.

View Article and Find Full Text PDF

Historically, evaluation of the upper extremity vasculature was performed using digital subtraction angiography. With the advancement of cross-sectional imaging and submillimeter isotropic data acquisition, CT angiography (CTA) has become an excellent noninvasive diagnostic tool for evaluation of the vasculature of the upper extremities. CTA allows quick evaluation of vessel patency and irregularity and achievement of the anatomic detail needed in preoperative planning.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!