A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In Vitro Assessment of Primary Stability of BoneTrust Sinus Implant Design. | LitMetric

The aim of this study was to analyze the primary stability of BoneTrust Sinus implants (BTSIs), which are intended to enable higher primary stability by their special design with reduced thread section in cases of reduced vertical bone availability, in comparison with standard BoneTrust implants (SBTIs) in vitro. A bone window 3 cm in length, 4 cm in width, and 3 cm in depth, resembling the maxillary bone window of the lateral sinus wall with 4 mm of residual bone height, was prepared at the dorsal side of freshly slaughtered bovine ribs. One single BTSI and a single SBTI with the same diameter (4 or 5 mm) were placed in each window. After implant placement, the implant stability quotient (ISQ) was measured by using resonance frequency analysis with an Osstell device. A total of 88 implants were placed. ISQ values varied between 63 and 84. Among the implants with 4-mm diameter, all BTSIs showed higher ISQ values compared with SBTIs. One-way analysis of variance showed a significant difference between BTSIs/SBTIs (P < .05). BTSIs with 4-mm diameter showed statistically higher values compared to BTSIs with 5-mm diameter (P < .05). Among the implants with 5-mm diameter, all SBTIs showed higher ISQ values compared to BTSIs but there was no significant difference. The use of 4-mm-diameter BTSIs could present higher ISQ values during simultaneous implant placement in conjunction with lateral sinus floor augmentation.

Download full-text PDF

Source
http://dx.doi.org/10.11607/prd.2562DOI Listing

Publication Analysis

Top Keywords

isq values
16
primary stability
12
higher isq
12
values compared
12
stability bonetrust
8
bonetrust sinus
8
bone window
8
lateral sinus
8
implant placement
8
4-mm diameter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!