Study Design: Retrospective study.

Purpose: To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients.

Overview Of Literature: C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for better fixation. But, this option is limited by the narrow pedicle width.

Methods: We have obtained computed tomography (CT) cervical spine data in 0.625 mm slices from our radiology department. The patients were adults. CTs were from May to August, 2015. The lateral mass screw length was measured using Margerl's technique and pedicle width and pedicle screw trajectory were determined in three-dimensional reformated images.

Results: CT scans of cervical spines of 94 patients were obtained and 188 lateral masses and pedicles of C7 vertebrae were measured. The mean lateral mass screw length was 13.2 mm (standard deviation [SD] 1.6 mm), mean outer pedicle width was 5.9 mm (SD 1.0 mm) and mean pedicle screw trajectory was 29.4 degrees (SD 3.6 degrees). Most (91.0%) of the pedicles had an outer diameter ≥4.5 mm.

Conclusions: The mean lateral mass screw length was longer when compared with other similar studies, while the mean outer pedicle width was narrower. Nearly 10% of the pedicles were unable to accommodate 3.5 mm screws. These findings favor the use of lateral mass screws to provide a safe and stable fixation for C7 vertebrae in Southern Chinese patients, while the final choice of fixation method should only be confirmed after careful preoperative planning with CT scan.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4995254PMC
http://dx.doi.org/10.4184/asj.2016.10.4.705DOI Listing

Publication Analysis

Top Keywords

lateral mass
32
mass screws
16
southern chinese
12
pedicle screws
12
mass screw
12
screw length
12
pedicle width
12
lateral
9
pedicle
9
quantitative anatomy
8

Similar Publications

Civil structures are prone to dynamic loadings such as strong winds or ground excitations where torsion becomes an ongoing issue. This arises from a lack of coincidence of the center of mass (CM) and rigidity (CR), known as eccentricity. Seismic design codes often introduce two types of eccentricity: inherent (geometric) and accidental.

View Article and Find Full Text PDF

In the last decade, pulmonary fungal infections such as invasive pulmonary aspergillosis (IPA) have increased in incidence due to the increased number of immunocompromised individuals. This increase is especially problematic when considering mortality rates associated with IPA are upwards of 70%. This high mortality rate is due to, in part, the length of time it takes to diagnose a patient with IPA.

View Article and Find Full Text PDF

The Multi-Component Structure of Core Strength.

J Funct Morphol Kinesiol

November 2024

Institute of Sport Science, School of Humanities and Social Sciences, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany.

Background/objectives: Core strength diagnostics often focus on measuring core endurance rather than maximal core strength or core power. This study investigates whether core strength can be considered as a general ability that can be measured by a single core strength test or whether it needs to be differentiated into several components.

Methods: Forty-two adult sports students ( = 20; = 22; age: 24.

View Article and Find Full Text PDF

Nothronychus graffami was a large therizinosaur represented by a single well-preserved individual from the Turonian Tropic Shale of southern Utah. It is characterized by an enlarged abdomen, small tail, and an extensively pneumatized axial skeleton, and is frequently regarded as herbivorous. Given the overall tail reduction and the development of a wide fused synsacrum with widely spaced acetabulae, it is reconstructed with an anteriorly rotated femur and a displaced resting ground reaction force anterior to the center of mass.

View Article and Find Full Text PDF

The authors present a case of an orbital apex venous malformation that presented with an intermittent oculomotor nerve palsy over a 15-year period. Radiologically, the lesion presented as a well-circumscribed orbital mass with T2 hyperintensity and enhancement that could only be demonstrated on 2-hour delayed phase imaging. The venous malformation was initially steroid-responsive but eventually became refractory to medical treatment alone.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!