A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pooled Nucleic Acid Amplification Test for Screening of Stool Specimens for Shiga Toxin-Producing Escherichia coli. | LitMetric

Shiga toxin-producing Escherichia coli (STEC)-associated enteric illness is attributed to O157 and non-O157 serotypes; however, traditional culture-based methods underdetect non-O157 STEC. Labor and cost of consumables are major barriers to implementation of the CDC recommendation to test all stools for both O157 and non-O157 serotypes. We evaluated the feasibility of a pooled nucleic acid amplification test (NAAT) as an approach for screening stool specimens for STEC. For retrospective evaluation, 300 stool specimens were used to create pools of 10 samples each. The sensitivity was 83% for the preenrichment pooling strategy and 100% for the postenrichment pooling strategy compared with those for individual NAAT results. The difference in cycle threshold (C) between individual and pooled NAAT results for specimens was significantly lower and more consistent for postenrichment pooling (stx mean = 3.90, stx mean = 4.28) than those for preenrichment pooling (excluding undetected specimens; stx mean = 9.34, stx mean = 8.96) (P ≤ 0.0013). Cost of consumables and labor time savings of 48 to 81% and 6 to 66%, respectively, were estimated for the testing of 90 specimens by the postenrichment pooled NAAT strategy on the basis of an expected 1 to 2% positivity rate. A 30-day prospective head-to-head clinical trial involving 512 specimens confirmed the sensitivity and labor savings associated with the postenrichment pooled NAAT strategy. The postenrichment pooled NAAT strategy described here is suitable for efficient large-scale surveillance of all STEC serotypes. Comprehensive detection of STEC will result in accurate estimation of STEC burden and, consequently, appropriate public health interventions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5078548PMC
http://dx.doi.org/10.1128/JCM.01373-16DOI Listing

Publication Analysis

Top Keywords

pooled naat
16
stool specimens
12
postenrichment pooled
12
naat strategy
12
pooled nucleic
8
nucleic acid
8
acid amplification
8
amplification test
8
screening stool
8
shiga toxin-producing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!