Background: To simplify extensive repair of acute DeBakey type I aortic dissection, ascending aorta and hemiarch replacement combined with modified triple-branched stent graft implantation was developed. The descriptions and early results of this technique are reported.
Methods: From August 2014 to September 2015, 116 patients with acute DeBakey type I aortic dissection underwent ascending aorta and hemiarch replacement combined with modified triple-branched stent graft implantation. Clinical data of all patients were retrospectively reviewed. Survivors were followed up prospectively by computed tomography angiography.
Results: The cardiopulmonary bypass time was 131.5 ± 10.7 minutes, the aortic cross-clamp time was 50.0 ± 9.9 minutes, and the selective cerebral perfusion and lower body arrest time was 17.2 ± 2.2 minutes. The in-hospital mortality rate was 3.4%. Two patients were lost during follow-up. One patient died of a cerebrovascular accident 2 months after discharge, and another died of chronic renal failure 5 months after discharge. At the 3-month postoperative scans, complete thrombus formation of the false lumen around the implanted modified triple-branched stent graft occurred in all survivors, at the diaphragmatic level in 69.7% patients, and at the superior mesenteric arterial level in 8.3% patients.
Conclusions: Extensive thoracic aorta repair of acute type I aortic dissection can be performed simply by combining ascending aorta and hemiarch replacement with modified triple-branched stent graft implantation. This technique can reduce the risk and technical difficulty of extensive thoracic aorta repair to levels close to those seen with ascending aorta and hemiarch graft replacement with open distal anastomosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.athoracsur.2016.06.017 | DOI Listing |
Sci Rep
January 2025
University of Ulsan, 93 Daehak-ro, Nam-gu, Ulsan, 680-749, Republic of Korea.
This study employed large eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) model to investigate transitional flow characteristics in an idealized model of a healthy thoracic aorta. The OpenFOAM solver pimpleFoam was used to simulate blood flow as an incompressible Newtonian fluid, with the aortic walls treated as rigid boundaries. Simulations were conducted for 30 cardiac cycles and ensemble averaging was employed to ensure statistically reliable results.
View Article and Find Full Text PDFAnn Vasc Surg
January 2025
Division of Vascular Surgery, University of Maryland, Baltimore, Maryland.
Background: Thoracic Endovascular Aortic Repair (TEVAR) reduced mortality for blunt aortic injury (BAI) from 30-50% to < 10%; however, penetrating traumatic aortic injury (PAI) remains highly lethal (>40% mortality). This study's goal is to determine outcomes of TEVAR for PAI.
Methods: Patients undergoing TEVAR for traumatic aortic injuries were identified from the Vascular Quality Initiative database from 2011-2022.
J Clin Med
January 2025
Department of Cardiovascular Surgery, Institute Insure, German Heart Center Munich, School of Medicine & Health, Technical University of Munich, Lazarettstrasse 36, 80636 Munich, Germany.
: In the presence of porcelain aorta (PA), transcatheter aortic valve replacement (TAVR) has become a class I therapeutic indication for the treatment of severe aortic valve stenosis. To date, few studies have analyzed the clinical outcomes of TAVR in PA patients. We aim to analyze the calcification patterns of the thoracic aorta in PA patients and to evaluate their clinical implications for TAVR procedures.
View Article and Find Full Text PDF: EnBloc resections of bone tumors of the spine are very demanding as the target to achieve a tumor-free margin specimen (sometimes impossible due to the extracompartimental tumor extension) is sometimes conflicting with the integrity of neurological functions and spine stability. : The surgical treatment of a huge multi-level chordoma of the thoracic spine with unusual extension is reported. Anteriorly, the tumor widely invaded the mediastinum and displaced the aorta; on the left side, it expanded in the subpleuric region; posteriorly, it was uncommonly distant 13 mm from the posterior wall.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Cardiovascular Surgery, Houston Methodist Hospital, 6550 Fannin St, Houston, TX 77030, USA.
: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!